testo 330-2 LL (O2 and COH2) flue gas set for service technicians and inspectors, incl.BLUETOOTH, rech. battery and calibration protocol; mains unit 100-240 V for mains operation or charging the rechargeable battery in the instrument; combustion air temperature probe, length 190 mm; Testo BLUETOOTH printer with mains unit; easyheat software testo 330 for PC; USB connection cable, instrument-PC; flue gas probe, length 300 mm, Ø 8 mm, Tmax. 500 °C; fine pressure probe; capillary hoses; surface probe angled 90 °C; connection cable surface probe; straight Pitot tube; heating check retrofit CD; basic system case with double floor for instrument, probes and further accessories
testo 330-2 LL (O2 and COH2) flue gas set for service techni...
Order-Nr. 0563 3372 72
Technical Data
General technical data | |
---|---|
Weight |
600 g (t3) |
Dimensions |
270 x 90 x 65 mm |
Operating temperature |
-5 to +45 °C |
Protection class |
IP40 |
Display size |
240 x 320 pixels |
Display function |
Colour graphic display |
Power supply |
Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A |
Maximum memory |
500,000 readings |
Storage temperature |
-20 to +50 °C |
Differential Pressure - Piezoresistive | |
---|---|
Measuring range |
±10000 Pa |
Accuracy |
±0.3 Pa (0 to 9.99 Pa) t3 ±3 % of mv (10 to 10000 Pa) t3 |
Flue gas O₂ | |
---|---|
Measuring range |
0 to 21 Vol.% |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Reaction time t₉₀ |
< 20 s |
Flue gas CO (with H₂-compensation) | |
---|---|
Measuring range |
0 to 8000 ppm |
Accuracy |
±10 ppm or ±10 % of mv (0 to 200 ppm) ±20 ppm or ±5 % of mv (201 to 2000 ppm) ±10 % of mv (2001 to 8000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 60 s |
Measuring rate |
0 to 500 ppm |
Flue gas COlow (with H₂-compensation) | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±2 ppm (0 to 3990.0 ppm) ±5 % of mv (40 to 500 ppm) |
Resolution |
1.0 ppm |
Reaction time t₉₀ |
< 40 s |
Flue gas NO | |
---|---|
Measuring range |
0 to 3000 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5 (101 to 2000 ppm) ±10 % of mv (2001 t1 3000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 30 s |
Flue gas Nolow | |
---|---|
Measuring range |
0 to 300 ppm |
Accuracy |
±2 ppm (0 to 39.9 ppm) ±5 % of mv (40 to 300 ppm) |
Resolution |
0.1 ppm |
Reaction time t₉₀ |
< 30 s |
Differential Pressure flue gas Draught - Piezoresistive | |
---|---|
Measuring range |
-9.99 to +40 hPa |
Accuracy |
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±1.5 % of mv (+3.01 to +40.00 hPa) |
Resolution |
0.01 hPa |
Temperature | |
---|---|
Measuring range |
-40 to +1200 °C |
Accuracy |
±0.5 °C (0 to +100.0 °C) ±0.5 % of mv (Remaining Range) |
Resolution |
0.1 °C (-40 to +999.9 °C) 1 °C (> +1000 °C) |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range |
0 to 120 % |
Resolution |
0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range |
0 to 99.9 % |
Resolution |
0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range |
0 to CO₂ max (Display range) |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Reaction time t₉₀ |
< 40 s |
Velocity / Volume flow | |
---|---|
Measuring range |
0.15 to 3 m/s |
Resolution |
0.1 m/s |
Pressure measurement | |
---|---|
Measuring range |
0 to +300 hPa |
Accuracy |
±0.5 hPa (0.0 to 50.0 hPa) ±1 % of mv (50.1 to 100.0 hPa) ±1.5 % of mv (Remaining Range) |
Resolution |
0.1 hPa |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range |
0 to 4000 ppm |
Accuracy |
±20 ppm (0 t1 400 ppm) ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 60 s |
Ambient CO | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (> 100 ppm) |
Resolution |
1 ppm |
Reaction time |
Approx. 35 s |
with CO probe
Ambient CO₂ | |
---|---|
Measuring range |
0 to 1 Vol.% 0 to 10000 ppm |
Accuracy |
±50 ppm or ±2 % of mv (0 to 5000 ppm) ±100 ppm or ±3 % of mv (5001 to 10000 ppm) |
Reaction time |
Approx. 35 |
with ambient CO₂ probe
Gas leak measurement for combustible gases (via gas leak detection probe) | |
---|---|
Measuring range |
0 to 10000 ppm CH₄ / C₃H₈; Display range |
Accuracy |
Signal optical display (LED) audible signal via buzzer |
Reaction time t₉₀ |
< 2 s |
with gas leak detection probe
Temperature (via the fine pressure probe) | |
---|---|
Measuring range |
-40 to +1200 °C max. (dependent on probe) |
Accuracy |
±0.5 °C (-40 to 100 °C) ±0.5 % of mv (Remaining Range) plus probe accuracy |
Resolution |
0.1 °C |