Flue gas analyzer with longlife gas sensors and integrated draught and gas zeroing
testo 330-2 LL
Order-Nr. 0563 3372 76
Details
Product Description
• High-resolution colour display for the graphic representation of your measurement data
• Extended measurement menus – such as gas pipe testing – for a comprehensive analysis of your heating system
• Logger function for easy long-term recording of the measurement curve
Technical Data
General technical data | |
---|---|
Weight |
600 g (without rechargeable battery) |
Dimensions |
270 x 90 x 65 mm |
Operating temperature |
-5 to +45 °C |
Display size |
240 x 320 pixels |
Display function |
Colour graphic display |
Power supply |
Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A |
Maximum memory |
500,000 readings |
Storage temperature |
-20 to +50 °C |
Differential Pressure - Piezoresistive | |
---|---|
Measuring range |
0 to 300 hPa |
Accuracy |
±0.5 hPa (0.0 to 50.0 hPa) ±1 % of mv (50.1 to 100.0 hPa) ±1.5 % of mv (Remaining Range) |
Resolution |
0.1 hPa |
Flue gas O₂ | |
---|---|
Measuring range |
0 to 21 Vol.% |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Reaction time t₉₀ |
< 20 s |
Flue gas CO (with H₂-compensation) | |
---|---|
Measuring range |
0 to 8000 ppm |
Accuracy |
±10 ppm or ±10 % of mv (0 to 200 ppm) ±20 ppm or ±5 % of mv (201 to 2000 ppm) ±10 % of mv (2001 to 8000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 60 s |
Flue gas COlow (with H₂-compensation) | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±2 ppm (0 to 39.9 ppm) ±5 % of mv (40 to 500 ppm) |
Resolution |
0.1 ppm |
Reaction time t₉₀ |
< 40 s |
CO determination (with H₂-compensation), automatic dilution | |
---|---|
Measuring range |
0 to 30000 ppm |
Accuracy |
±100 ppm (0 to 1000 ppm) ±10 % of mv (1001 to 30000 ppm) |
Resolution |
1 ppm |
Flue gas NO | |
---|---|
Measuring range |
0 to 3000 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (101 to 2000 ppm) ±10 % of mv (2001 to 3000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 30 s |
Flue gas Nolow | |
---|---|
Measuring range |
0 to 300 ppm |
Accuracy |
±2 ppm (0 to 39.9 ppm) ±5 % of mv (40 to 300 ppm) |
Resolution |
0.1 ppm |
Reaction time t₉₀ |
< 30 s |
Differential Pressure flue gas Draught - Piezoresistive | |
---|---|
Measuring range |
-9.99 to +40 hPa |
Accuracy |
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±1.5 % of mv (+3.01 to +40.00 hPa) |
Resolution |
0.01 hPa |
Temperature | |
---|---|
Measuring range |
-40 to +1200 °C * |
Accuracy |
±0.5 °C (0 to +100.0 °C) ±0.5 % of mv (Remaining Range) |
Resolution |
0.1 °C (-40 to +999.9 °C) 1 °C (> +1000 °C) |
* Measuring range depends on the connected flue gas probe
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range |
0 to 120 % |
Resolution |
0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range |
0 to 99.9 % |
Resolution |
0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range |
0 to CO₂ max (Display range) |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Reaction time t₉₀ |
< 40 s |
Pressure measurement | |
---|---|
Measuring range |
0 to +300 hPa |
Accuracy |
±0.5 hPa (0.0 to 50.0 hPa) ±1 % of mv (50.1 to 100.0 hPa) ±1.5 % of mv (Remaining Range) |
Resolution |
0.1 hPa |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range |
0 to 4000 ppm |
Accuracy |
±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 60 s |
Ambient CO | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (> 100 ppm) |
Resolution |
1 ppm |
Reaction time |
Approx. 35 s |
with CO probe 0632 3331
Ambient CO₂ | |
---|---|
Measuring range |
0 to 1 Vol.% 0 to 10000 ppm |
Accuracy |
±75 ppm or ±3 % of mv (0 to 5000 ppm) ±150 ppm or ±5 % of mv (5001 to 10000 ppm) |
Reaction time |
Approx. 35 s |
with ambient CO₂ probe 0632 1240
Gas leak measurement for combustible gases (via gas leak detection probe) | |
---|---|
Measuring range |
0 to 10000 ppm CH₄ / C₃H₈; Display range |
Accuracy |
Signal optical display (LED) audible signal via buzzer |
Reaction time t₉₀ |
< 2 s |
with gas leak detection probe 0632 3330
Probes
Probes
Order Number: 0632 3331
Order Number: 0632 3330
Downloads
Software / Firmware
-