Flue gas, gas and particle

The worldwide uninterrupted pollution of the atmosphere and more and more rules and regulations mean that flue gas analysis and emission control is becoming more and more important. It serves to reduce pollutant emission from combustion systems and it meets the objective of using energy as efficiently as possible.

31 products or recommendations for Flue gas
  • Connection hose, silicone

    Order-Nr. 0554 0440

    Use the connection hose to connect suitable Pitot tubes and pressure probes with one another. The hose is made of silicone and has a max. load capacity of up to 700 hPa (mbar).
    • For the connection of Pitot tube and pressure probe

    • Length of 5 m

  • CO replacement filter for sensor

    Order-Nr. 0554 4100

    Cross sensitivity to NO and SO2 is blocked by the CO sensor replacement filter during flue gas analysis.
    • Exchangeable probe for CO sensor

    • Blocks cross sensitivity to NO and SO2

  • Spare sintered filters (2 off)

    Order-Nr. 0554 3372

    The spare sintered filter enables you to replace your probe’s pre-filter without any problem.
    • For replacing the probe pre-filter

    • Ideal for measuring flue gases with a high dust content

    • Protects against damage caused by dust

  • NO replacement filter for sensor

    Order-Nr. 0554 4150

    Cross sensitivity to SO2 is blocked by the NO sensor replacement filter during flue gas analysis.
    • Exchangeable probe for NO sensor

    • Blocks cross sensitivity to SO2

  • Probe shaft, length 335 mm, incl. cone, Ø 8 mm, Tmax 1000 °C

    Order-Nr. 0554 8764

    The probe shaft with integrated thermocouple enables temperature measurements up to 1000°C. The quick-change click system enables the probe shaft to be fixed onto the appropriate handle really easily.
    • Easy probe shaft change via quick-change click system

    • For temperature measurements up to 1000°C

    • Length of 335 mm

  • Probe shaft, length 700 mm, incl. cone, Ø 8 mm, Tmax. 1000 °...

    Order-Nr. 0554 8765

    The probe shaft with integrated thermocouple enables temperature measurements up to 1000°C. The quick-change click system enables the probe shaft to be fixed onto the appropriate handle really easily.
    • Easy probe shaft change via quick-change click system

    • For temperature measurements up to 1000°C

    • Length of 700 mm

  • NOlow replacement sensor

    Order-Nr. 0393 0152

    NOlow replacement sensor for flue gas measurement. Particularly practical: you can replace the sensor yourself – the precalibrated sensor is simply plugged into the appropriate flue gas analyzer.
    • For measuring NOlow

    • Simply change sensor yourself on site

    • Precalibrated

  • NO2 replacement sensor

    Order-Nr. 0393 0200

    NO2 replacement sensor for flue gas measurement. Particularly practical: you can replace the sensor yourself – the precalibrated sensor is simply plugged into the appropriate flue gas analyzer.
    • For measuring NO2

    • Simply change sensor yourself on site

    • Precalibrated

  • NO replacement sensor

    Order-Nr. 0393 0150

    NO replacement sensor for flue gas measurement. Particularly practical: you can replace the sensor yourself – the precalibrated sensor is simply plugged into the appropriate flue gas analyzer.
    • For measuring NO

    • Simply change sensor yourself on site

    • Precalibrated

  • NOlow retrofit sensor

    Order-Nr. 0554 2152

    Equip your flue gas analyzer with an additional measurement parameter. This retrofit sensor enables NOlow measurement in the flue gas and ensures activation of the measurement parameter in the flue gas analyzer. Particularly practical: you can insert the precalibrated sensor into the compatible measuring instrument effortlessly yourself.
    • For measuring NOlow

    • Simply insert sensor yourself

    • Precalibrated

  • O2 replacement sensor

    Order-Nr. 0393 0000

    O2 replacement sensor for flue gas measurement. Particularly practical: you can replace the sensor yourself – the precalibrated sensor is simply plugged into the appropriate flue gas analyzer.
    • For measuring O2

    • Simply change sensor yourself on site

    • Precalibrated

  • COlow (H2-compensated) replacement sensor

    Order-Nr. 0393 0102

    COlow (H2-compensated) replacement sensor for flue gas measurement. Particularly practical: you can replace the sensor yourself – the precalibrated sensor is simply plugged into the appropriate flue gas analyzer.
    • For measuring COlow (H2-compensated)

    • Simply change sensor yourself on site

    • Precalibrated

  • CO (H2-compensated) retrofit sensor

    Order-Nr. 0554 2104

    Equip your flue gas analyzer with an additional measurement parameter. This retrofit sensor enables H2-compensated CO measurement in the flue gas and ensures activation of the measurement parameter in the flue gas analyzer. Particularly practical: you can insert the precalibrated sensor into the compatible measuring instrument effortlessly yourself.
    • For measuring CO (H2-compensated)

    • Simply insert sensor yourself

    • Precalibrated

  • SO2 replacement sensor

    Order-Nr. 0393 0250

    SO2 replacement sensor for flue gas measurement. Particularly practical: you can replace the sensor yourself – the precalibrated sensor is simply plugged into the appropriate flue gas analyzer.
    • For measuring SO2

    • Simply change sensor yourself on site

    • Precalibrated

31 Products found