IAQ probe for analyzing Indoor Air Quality, CO2

Order-Nr.  0632 1543

  • 4 functions in one probe: measurement of CO2, humidity, temperature and absolute pressure

  • Rapid checking of the indoor climate

  • Prevention of poor air quality in indoor rooms via CO2 measurement

  • Intelligent calibration concept

IAQ probe for analyzing Indoor Air Quality, CO2, temperature and absolute pressure measurement, incl. table tripod

Price on Request

Product Description

IAQ probe for analyzing Indoor Air Quality, CO<sub>2</sub>, humidity measurement, temperature and absolute pressure measurement, incl. table tripod

 

Delivery Scope

Indoor air quality probe including desktop tripod.
Note: you need a plug-in head cable (0430 0100) for this probe.
Temperature - NTC

Measuring range

0 to +50 °C

Accuracy

±0.5 °C

Resolution

0.1 °C

Humidity - Capacitive

Measuring range

0 to +100 %RH

Accuracy

±(1.8 %RH + 0.7 % of mv)

Resolution

0.1 %RH

Absolute Pressure

Measuring range

+700 to +1100 hPa

Accuracy

±3.0 hPa

Resolution

0.1 hPa

Ambient CO₂

Measuring range

0 to +10000 ppm

Accuracy

±(75 ppm + 3 % of mv)

0 to +5000 ppm

±(150 ppm + 5 % of mv)

5001 to +10000 ppm

Resolution

1 ppm

General technical data

Diameter probe shaft

21 mm

Length probe

305 mm