1. Home
  2. Thermal flow velocity probe (hot wire) Ø 10 mm, bendable by ...

Hot wire probe (Ø 10 mm) - for flow, temperature, humidity and pressure

0635 1543
  • 4 functions in 1 probe: measurement of flow, temperature, humidity and absolute pressure
  • With robust, non-rotatable telescope (can be extended to 1100 mm)
  • Intelligent calibration concept
  • Flow measuring range: 0 to +20 m/s
  • Product no longer available. Have you checked out its successor?
    Why not enjoy the benefits that it has to offer:
    >> To the product (fixed cable)
    >> To the product (wireless, with Bluetooth)
    Please note that the successor products are only compatible with testo 400 or testo 440.
    Use the hot wire probe (thermal anemometer) to determine flow velocity and volume flow in ventilation ducts or at wall/ceiling outlets. It is particularly suitable for low and medium flow velocities up to +20 m/s. The probe can also measure temperature, humidity and absolute pressure simultaneously.

    The hot wire probe is equipped with a robust, non-rotatable telescope, which can be extended to a maximum length of 1100 mm. The immersion depth is easy to read off thanks to the scaling on the telescope.

    For easier handling, the probe can be bent up to an angle of 90°. On the handle there is a practical measuring button, which activates storage of the readings. So you can fully focus on the positioning of the probe in the ventilation duct.

    Intelligent calibration concept

    The probe offers maximum digital measurement reliability. The digital probe allows readings to be processed directly in the probe. This technology eliminates instrument measurement uncertainty. The probe can be returned on its own (without the measuring instrument) for calibration. Calculating the determined calibration data in the probe generates a zero-error display.

    Hot wire probe (Ø 10 mm) with telescope (can be extended to 1100 mm).

    Note: you need a plug-in head cable (0430 0100) for this probe.

    Temperature - NTC

    Measuring range
    -20 to +70 °C
    Accuracy
    ±0.5 °C

    Humidity - Capacitive

    Measuring range
    0 to 100 %RH
    Accuracy
    ±(1.8 %RH + 0.7 % of mv)

    Absolute Pressure

    Measuring range
    +700 to +1100 hPa
    Accuracy
    ±3 hPa