Flue gas analyzer with longlife gas sensors and integrated draught and gas zeroing
testo 330-2 LL
Order-Nr. 0563 3372 77
Details
Product Description
• High-resolution colour display for the graphic representation of your measurement data
• Extended measurement menus – such as gas pipe testing – for a comprehensive analysis of your heating system
• Logger function for easy long-term recording of the measurement curve
Technical Data
General technical data | |
---|---|
Weight |
600 g (without rechargeable battery) |
Dimensions |
270 x 90 x 65 mm |
Operating temperature |
-5 to +45 °C |
Display size |
240 x 320 pixels |
Display function |
Colour graphic display |
Power supply |
Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A |
Maximum memory |
500,000 readings |
Storage temperature |
-20 to +50 °C |
Differential Pressure - Piezoresistive | |
---|---|
Measuring range |
±10000 Pa |
Accuracy |
±0.3 Pa (0 to 9.99 Pa) plus ±1 Digit ±3 % of mv (10 to 10000 Pa) plus ±1 Digit |
Flue gas O₂ | |
---|---|
Measuring range |
0 to 21 Vol.% |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Reaction time t₉₀ |
< 20 s |
Flue gas CO (with H₂-compensation) | |
---|---|
Measuring range |
0 to 8000 ppm |
Accuracy |
±10 ppm or ±10 % of mv (0 to 200 ppm) ±20 ppm or ±5 % of mv (201 to 2000 ppm) ±10 % of mv (2001 to 8000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 60 s |
Flue gas COlow (with H₂-compensation) | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±2 ppm (0 to 39.9 ppm) ±5 % of mv (40 to 500 ppm) |
Resolution |
0.1 ppm |
Reaction time t₉₀ |
< 40 s |
CO determination (with H₂-compensation), automatic dilution | |
---|---|
Measuring range |
0 to 30000 ppm |
Accuracy |
±100 ppm (0 to 1000 ppm) ±10 % of mv (1001 to 30000 ppm) |
Resolution |
1 ppm |
Flue gas NO | |
---|---|
Measuring range |
0 to 3000 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (101 to 2000 ppm) ±10 % of mv (2001 to 3000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 30 s |
Flue gas Nolow | |
---|---|
Measuring range |
0 to 300 ppm |
Accuracy |
±2 ppm (0 to 39.9 ppm) ±5 % of mv (40 to 300 ppm) |
Resolution |
0.1 ppm |
Reaction time t₉₀ |
< 30 s |
Differential Pressure flue gas Draught - Piezoresistive | |
---|---|
Measuring range |
-9.99 to +40 hPa |
Accuracy |
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±1.5 % of mv (+3.01 to +40.00 hPa) |
Resolution |
0.01 hPa |
Temperature | |
---|---|
Measuring range |
-40 to +1200 °C |
Accuracy |
±0.5 °C (0 to +100.0 °C) ±0.5 % of mv (Remaining Range) |
Resolution |
0.1 °C (-40 to +999.9 °C) 1 °C (> +1000 °C) |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range |
0 to 120 % |
Resolution |
0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range |
0 to 99.9 % |
Resolution |
0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range |
0 to CO₂ max (Display range) |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Reaction time t₉₀ |
< 40 s |
Velocity / Volume flow | |
---|---|
Measuring range |
0.15 to 3 m/s |
Resolution |
0.1 m/s |
Pressure measurement | |
---|---|
Measuring range |
0 to +300 hPa |
Accuracy |
±0.5 hPa (0.0 to 50.0 hPa) ±1 % of mv (50.1 to 100.0 hPa) ±1.5 % of mv (Remaining Range) |
Resolution |
0.1 hPa |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range |
0 to 4000 ppm n1{#0} t1 n2{#0} {%S2} |
Accuracy |
±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 60 s |
Ambient CO | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (> 100 ppm) |
Resolution |
1 ppm |
Reaction time |
Approx. 35 s |
with CO probe
Ambient CO₂ | |
---|---|
Measuring range |
0 to 1 Vol.% 0 to 10000 ppm |
Accuracy |
±50 ppm or ±2 % of mv (0 to 5000 ppm) ±100 ppm or ±3 % of mv (5001 to 10000 ppm) |
Reaction time |
Approx. 35 s |
with ambient CO₂ probe
Gas leak measurement for combustible gases (via gas leak detection probe) | |
---|---|
Measuring range |
0 to 10000 ppm CH₄ / C₃H₈; Display range |
Accuracy |
Signal optical display (LED) audible signal via buzzer |
Reaction time t₉₀ |
< 2 s |
with gas leak detection probe
Temperature (via the fine pressure probe) | |
---|---|
Measuring range |
-40 to +1200 °C max. (dependent on probe) |
Accuracy |
±0.5 °C (-40 to 100 °C) ±0.5 % of mv (Remaining Range) plus probe accuracy |
Resolution |
0.1 °C |
Probes
Probes
Order Number: 0600 3692
Order Number: 0600 9760
Order Number: 0600 9787
Order Number: 0632 3331
Accessories
Accessories
Accessories for probes
Instruments / options
Measurement cells
Downloads
Product Brochures
Software
-
Update-Kit / Bootloader (V1.22, EXE, 381 KB) If the firmware update does not start under Windows 8.1 or Windows 10, a new bootloader must be installed on the measuring device once.
A description and all necessary files can be found under the search term: Update-Kit / Bootloader -
Testo ZIV driver ZIV 2000 for testo 320 and testo 330 (ZIP, 8.8 MB) Testo ZIV driver in the 2000 version. The Testo ZIV driver is used to connect the testo 320 and testo 330 measuring instruments to an application program (sweeping district administration program) according to the interface Version 2.0 defined by the Zentralverband des Schornsteinfegerhandwerks (Central Association of Chimney Sweeps, ZIV). Please check with the manufacturer of your application program as to whether this interface is supported. If Microsoft .NET Framework 4.0 has not been installed on the computer, it must be downloaded from the Microsoft website and installed on the system.
-
PC Software testo EasyHeat (for testo 300, 312-4, 320, 324, 330, 380) (v2.12 SP7, text/x-html, 1 KB)