  • External sample gas conditioner

    Order-Nr. 0554 3501

    You can rely on accurate measurement results, even when carrying out measurements on very humid flue gas. With the gas cooler, you can easily minimize measurement inaccuracies due to water vapour.
    • Reduction of exhaust gas humidity increases measurement accuracy

    • Small design and low weight thanks to sophisticated gas path

    • Fast readiness thanks to easy connection and commissioning

    • Operation independently of power grid thanks to rechargeable powerbank
       

  • testo 190 CFR software - CFR software

    Order-Nr. 0554 1901

    Effective support for your validation and qualification tasks. From the simultaneous programming and readout of up to eight CFR data loggers, through comprehensive data analysis, to audit-relevant reporting – the 21 CFR Part 11-compliant testo 190 CFR software is efficient and intuitive.
    • Full, audit-relevant documentation with just the click of a mouse

    • Optimum support with the measurement process: the clear software structure guides every user intuitively through the process step by step

    • No data export to Excel needed

    • Readout of up to 254 data loggers possible in one validation process

  • IAQ data logger for long-term measurements

    Order-Nr. 0577 0400

    For long-term monitoring of the indoor air quality: Use the IAQ data logger as a stand-alone measuring unit for carrying out long-term measurements with the testo 400 IAQ measuring instrument. While the stand-alone data logger is carrying out the IAQ measurement, you can use the IAQ measuring instrument for measurements elsewhere.
    • Data logger configurable via testo 400 universal IAQ instrument

    • Compatible with probes for measuring the comfort level, turbulence, radiant heat, CO2, CO, illuminance, air flow velocity, humidity and temperature

    • Stand-alone data logger for long-term measurements up to 2 weeks

    • Connect up to six fixed cable probes at the same time

  • USB interface for data loggers

    Order-Nr. 0572 0500

    Use the USB interface to transmit the data logger's readings to the PC. Using the latest version of the testo ComSoft software, you can read out and analyze the readings - and you can also programme the data logger individually.
    • For transferring readings to your PC

    ₱7 966.00
    excl. VAT
  • International mains unit

    Order-Nr. 0554 1096

    Use the mains unit for mains operation of your measuring instrument or for battery charging in the instrument. It is suitable for international use.
    • For mains operation or charging batteries in the instrument

    • 100-240 V AC / 6.3 V DC

  • testovent 417 - funnel set for volume flow measurement

    Order-Nr. 0563 4170

    Use the testovent 417 funnel set (in conjunction with the appropriate measuring equipment) for measuring the volume flow at ventilation grilles and plate outlets quickly and conveniently.
    • Convenient, quick volume flow measurement

    • With the funnel set, the time-consuming loop method is a thing of the past

    • Suitable for outlets up to 300 x 300 mm

    • Easy to assemble

  • Connection hose, silicone

    Order-Nr. 0554 0440

    Use the connection hose to connect suitable Pitot tubes and pressure probes with one another. The hose is made of silicone and has a max. load capacity of up to 700 hPa (mbar).
    • For the connection of Pitot tube and pressure probe

    • Length of 5 m

  • Spare head for leak detector - for CFC, HFC (partially and fully halogenated), H2

    Order-Nr. 0554 3180

    Use this spare head for all common refrigerants CFC, HFC (partially and fully halogenated) and H2 to easily replace the sensor head on your leak detector.
    • Spare head for all common refrigerants CFC, HFC (partially and fully halogenated), H2

    • Extremely high sensitivity of ˂3g/a enables detection of even the smallest leaks

    • Easy sensor head replacement

    ₱10 085.00
    excl. VAT
  • Alarm module (visual + acoustic)

    Order-Nr. 0572 9999

    Alarm module (visual + acoustic), can be connected to base alarm relay. Ø 70 × 164 mm, 24 V AC/DC/320 mA, steady red light, continuous tone: Buzzer approx. 2.4 kHz (mains unit 0554 1749 required).
  • Battery small - battery small

    Order-Nr. 0515 1900

    The battery for data loggers takes just seconds to install, because it fits perfectly when screwed into the logger. This means you do not need to worry about any damage to the data logger as a result of fitting the battery.
    • Small format for space-saving use

    • Can be used at temperatures between -20 and +140 °C

    • Service life of 250 operating hours

    • Changing the battery takes just seconds, saving time and increasing efficiency

  • Battery large - battery large

    Order-Nr. 0515 1901

    The battery for data loggers takes just seconds to install, because it fits perfectly when screwed into the logger. This means you do not need to worry about any damage to the data logger as a result of fitting the battery.
    • Changing the battery takes just seconds, saving time and increasing efficiency

  • Freeze-drying probe holder (puck) - Lyophilization probe holder

    Order-Nr. 0554 1907

    The probe holder ensures precise measurement of the surface temperature in a freeze-drying system. To do this, secure the data logger's flexible temperature probe in the slot of the probe holder. The weight of the probe holder ensures that the temperature probe is in direct contact with the surface.
    • Probe holder for precise measurement of the surface temperature (plate temperature)

    • Enables direct contact with the surface – the ambient air has no influence on the measurement result

  • Retaining clamp (10 off)

    Order-Nr. 0554 0297

    In combination with cable ties, the retaining clamp enables easy and safe securing of the data logger, e.g. in sterilization systems. Particularly hygienic: the retaining clamp leaves no residues behind in the product or the system, such as those which arise when using adhesive tape.
    • Easy and safe securing of the data logger

    • Reusable multiple times

    • With practical thread for screwing onto the data logger

  • Distance adapter short (10 off)

    Order-Nr. 0554 0298

    The distance adapter is used to fix the data logger securely in the programming and readout unit. This enables reliable programming and readout of the logger.
    • For securing the logger in the programming and readout unit

  • Distance adapter long (10 off)

    Order-Nr. 0554 0299

    The distance adapter is used to fix the data logger securely in the programming and readout unit. This enables reliable programming and readout of the logger.
    • For securing the logger in the programming and readout unit

  • Can and bottle bushing

    Order-Nr. 0554 0458

    This accessory is impressive when it comes to handling and saves time with temperature monitoring in pasteurization and sterilization processes: the can and bottle bushing is screwed directly into the can or bottle top and tightened. All you need to do for the measurement is to guide the logger's temperature probe through the opening and secure it using the union nut.
    • Innovative: fitted by directly screwing it on manually

    • Easy attachment of the data logger on cans and bottles

    • Can be fitted without any pre-drilling

    • Enables precise, reproducible measurement results