testo 330-2 LL

Order-Nr.  0563 3372 76

Flue gas analyzer with longlife gas sensors and integrated draught and gas zeroing

SAR 8 028.00
excl. VAT

Product Description

Thanks to the new instrument functions, the Testo flue gas analyzers of the new testo 330-LL series now offer you even more professional and reliable support. These are the main features:
• High-resolution colour display for the graphic representation of your measurement data
• Extended measurement menus – such as gas pipe testing – for a comprehensive analysis of your heating system
• Logger function for easy long-term recording of the measurement curve

 

Differential Pressure - Piezoresistive

Measuring range

0 to 300 hPa

Accuracy

±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 hPa

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 20 s

Flue gas CO (with H₂-compensation)

Measuring range

0 to 8000 ppm

Accuracy

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 8000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 s

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 500 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 40 s

CO determination (with H₂-compensation), automatic dilution

Measuring range

0 to 30000 ppm

Accuracy

±100 ppm (0 to 1000 ppm)

±10 % of mv (1001 to 30000 ppm)

Resolution

1 ppm

Flue gas NO

Measuring range

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 30 s

Flue gas Nolow

Measuring range

0 to 300 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 300 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 30 s

Flue gas Draught

Measuring range

-9.99 to +40 hPa

Accuracy

±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.01 hPa

Temperature

Measuring range

-40 to +1200 °C *

Accuracy

±0.5 °C (0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °C (-40 to +999.9 °C)

1 °C (> +1000 °C)

* Measuring range depends on the connected flue gas probe

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 s

Pressure measurement

Measuring range

0 to +300 hPa

Accuracy

±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 hPa

Flue gas CO (without H₂-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 s

Ambient CO

Measuring range

0 to 500 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (> 100 ppm)

Resolution

1 ppm

Reaction time

Approx. 35 s

with CO probe 0632 3331

Ambient CO₂

Measuring range

0 to 1 Vol.%

0 to 10000 ppm

Accuracy

±75 ppm or ±3 % of mv (0 to 5000 ppm)

±150 ppm or ±5 % of mv (5001 to 10000 ppm)

Reaction time

Approx. 35 s

with ambient CO₂ probe 0632 1240

Gas leak measurement for combustible gases (via gas leak detection probe)

Measuring range

0 to 10000 ppm CH₄ / C₃H₈; Display range

Accuracy

Signal optical display (LED) audible signal via buzzer

Reaction time t₉₀

< 2 s

with gas leak detection probe 0632 3330

General technical data

Dimensions

270 x 90 x 65 mm

Operating temperature

-5 to +45 °C

Display size

240 x 320 pixels

Display function

Colour graphic display

Power supply

Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A

Maximum memory

500,000 readings

Storage temperature

-20 to +50 °C

Weight

600 g (without rechargeable battery)

Software / Firmware