testo 922 - Digital temperature meter

Order-Nr.  0560 9221

  • Temperature measurements and temperature difference display

  • Wide measuring range from -50 °C to 1 000 °C

  • Connecting points for two type K temperature sensors; wireless connectivity for a third temperature sensor

  • Wide range of optional sensors

Temperature measurements; measurements with up to three temperature sensors; direct display of temperature differences: the testo 922 digital temperature meter is ideal for professional use in the fields of heating, plumbing and air conditioning.

This meter uses a sensor to start up.

Click here for filter selection.

Product Description

The testo 922 digital temperature meter measures temperatures and determines the temperature difference in a matter of seconds. The meter comes with connecting points for up to two temperature sensors and wireless connectivity for a third sensor.
 

At-a-glance look at all the features

  • Connecting points for 2 optional type K temperature sensors
  • Wireless connectivity for a third temperature sensor
  • Temperature values and temperature difference directly visible in display
  • Permanent display of min and max values
  • Hold function that freezes the last reading
     

The testo 922 digital temperature meter – accessories and sensors 

  • There is a wide selection of optional temperature and wireless sensors to help you carry out your temperature measurements
  • The testo protocol printer allows you to print out on site; the cyclic printing can be used in  adjustable (i.e. one-minute) intervals
  • The durable, IP65 rated TopSafe protective case protects you digital temperature meter against impact and dirt and water ingress
     

The testo 922 digital temperature meter – areas of application

Professionals in the fields of heating, plumbing and air conditioning are quick to appreciate the benefits which the compact, easy-to-use testo 922 digital temperature meter has to offer. The testo 922 measures temperatures quickly and accurately and determines the temperature difference directly. This allows you to carry out your inspections and checks quickly and efficiently. There’s also an optional testo turbo printer which allows you to print out on site.

 

Delivery Scope

testo 922 digital temperature meter, calibration certificate, batteries.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +1000 °C

Accuracy

±(0.5 °C + 0.3 % of mv) (-40 to +900 °C)

±(0.7 °C + 0.5 % of mv) (Remaining Range)

Resolution

0.1 °C (-50 to +199.9 °C)

1 °C (Remaining Range)

General technical data

Dimensions

182 x 64 x 40 mm

Operating temperature

-20 to +50 °C

Housing

ABS

Number of channels

2-channel

Battery type

9V block battery, 6F22

Battery life

200 h (connected probe, backlight off); 45 h (radio mode, backlight off); 68 h (connected probe, backlight always on); 33 h (radio mode, backlight always on)

Storage temperature

-40 to +70 °C

Weight

171 g

Air probes

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

200 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Food probes

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +400 °C

Accuracy

Class 2 ²⁾

Reaction time

7 s

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +230 °C

Accuracy

Class 1 ²⁾

Reaction time

15 s

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Radio handles with probe head for air and immersion/penetration meas.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +350 °C

Short-term to: +500 °C

Accuracy

±(0.5 °C + 0.3 % of mv) (-40 to +500 °C

±(0.7 °C + 0.5 % of mv) (Remaining Range)

Resolution

0.1 °C (-50 to +199.9 °C)

1.0 °C Remaining Range

Reaction time

(in water) 10 s

Radio handles with probe head for surface measurement

Price on Request
Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +350 °C

Short-term to: +500 °C

Accuracy

Radio handle:

±(0.5 °C + 0.3 % of mv) (-40 to +500 °C)

±(0.7 °C + 0.5 % of mv) (Remaining Range)

T/C probe head: Class 2

Resolution

0.1 °C (-50 to +199.9 °C)

1.0 °C Remaining Range

Reaction time

5 s

Radio immersion/penetration probes

Temperature - NTC

Measuring range

-50 to +275 °C

Accuracy

±0.5 °C (-20 to +80 °C)

±0.8 °C (-50 to -20.1 °C)

±0.8 °C (+80.1 to +200 °C)

±1.5 °C (Remaining Range)

Resolution

0.1 °C

Reaction time

(in water) 12 s

Surface probes

Price on Request
Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +130 °C

Accuracy

Class 2 ²⁾

Reaction time

5 s

2) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

0 to +300 °C

Accuracy

Class 2 *

Reaction time

5 s

* According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +300 °C

Accuracy

Class 2 ¹⁾

Reaction time

3 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

20 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +300 °C

hort-term to 500°C

Accuracy

Class 2 ¹⁾

Reaction time

3 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

30 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +250 °C

Accuracy

Class 2 ¹⁾

Reaction time

t99 = 3 s (t3)

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Price on Request
Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +130 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +100 °C , short-term up to +130 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +170 °C

Accuracy

Class 2 ¹⁾

Reaction time

150 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Magnetic probe (TC Type K)

Order Number: 0602 4892

Price on Request
Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +400 °C

Accuracy

Class 2 ¹⁾

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Price on Request
Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +120 °C

Accuracy

Class 1 ¹⁾

Reaction time

90 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Thermocouples

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50.0 to +400.0 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - TC Type K (NiCr-Ni)

Measuring range

-50 to +250 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

immersion/ penetration probes

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

2 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

7 s

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type K (NiCr-Ni)

Measuring range

-60 to +800 °C

Accuracy

Class 1 ¹⁾

Reaction time

3 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - TC Type K (NiCr-Ni)

Measuring range

-200 to +1300 °C

Accuracy

Class 1 ¹⁾

Reaction time

4 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Immersion tip, flexible, TC Type K

Order Number: 0602 5792

Price on Request
Temperature - TC Type K (NiCr-Ni)

Measuring range

-200 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

5 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Immersion tip, flexible, TC Type K

Order Number: 0602 5793

Price on Request
Temperature - TC Type K (NiCr-Ni)

Measuring range

-200 to +40 °C

Class 3 ¹⁾

Reaction time

5 s

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Accessories for measuring instrument

9V rech. battery for instrument

Order Number: 0515 0025

Price on Request
Recharger for 9V rechargeable battery

Order Number: 0554 0025

Price on Request

Additional accessories

Handle for attachable measurement tips

Order Number: 0409 1092

Price on Request
Price on Request
Price on Request

Cases

Order Number: 0516 1200

Price on Request

Order Number: 0516 1201

Price on Request

Printer and accessories

Price on Request

Transport and Protection

Case for measuring instrument and probes

Order Number: 0516 0210

Price on Request
TopSafe, protects from impact and dirt

Order Number: 0516 0222

Price on Request

Flow and return temperature measurement on heating systems

To ensure the heating system is set correctly and efficiently, the flow and return temperatures must be measured. If it is not set correctly, either the requisite heat will not be provided or too much energy will be injected into an overly high flow temperature, i.e. the output from the energy is poor.

testo 922 advantages:

  • Quick and easy measurement of the differential temperature with pipe wrap probes
  • Also optionally available with radio probes for wireless measurement
  • Display of minimum and maximum measuring values
  • Immediate printing of measuring values via optional wireless printer