The testo 327-1 Flue Gas Analyser offers a robust and simple entry into flue gas analysis for domestic boilers. It measures O2 & CO , and will calculate ratio, CO2, etc. The 4-line LED display can be configured to the users requirements, and its back-lighting function guarantees an easy-to-read display even if lighting conditions are unfavourable. The analyser stands out on account of its easy menu navigation and ergonomic housing as well as its durability.
testo 327-1 - Flue Gas Analyser (advanced kit)
Order-Nr. 0563 3203 81
Details
Product Description
Overview
Advanced kit features include :
- 4,000ppm CO sensor with automatic pump shut off to help prevent saturation.
- 7 user selectable fuels
- Rechargable Li-ion battery
- Adaptors and accesories for pressure measurement, and differential temperature clamp probes supplied
- Testo IR printer
- Soft carry case with shoulder strap
Delivery Scope
Technical Data
General technical data | |
---|---|
Weight |
(with probe) Approx. 700 g |
Dimensions |
201 x 83 x 44 mm |
Operating temperature |
-5 to +45 °C |
Display type |
LCD (Liquid Crystal Display) |
Display function |
Backlit 2-line display |
Power supply |
Battery: 1500 mAh, mains unit 5V/1A |
Storage temperature |
-20 to +50 °C |
Temperature - TC Type K (NiCr-Ni) | |
---|---|
Measuring range |
-40.00 to +600.00 °C |
Accuracy |
±0.50 °C (0 to 99.90 °C) ±0.50 °C (100 to 600 °C) |
Resolution |
0.1 °C |
Reaction time |
< 50 s |
Temperature (ambient temperature)
Flue gas O₂ | |
---|---|
Measuring range |
0 to 21 Vol.% |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Reaction time t₉₀ |
30 s |
Differential Pressure flue gas Draught - Piezoresistive | |
---|---|
Measuring range |
-40.0 to +40.0 hPa |
Accuracy |
±0.02 hPa (-0.50 to +0.60 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±1.50 % of mv (3.01 to +40.0 hPa) |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range |
0 to 120 % |
Resolution |
0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range |
0 to 99.0 % |
Resolution |
0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range |
0 to CO₂ max (Display range) |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Reaction time t₉₀ |
< 40 s |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range |
0 to 4000 ppm |
Accuracy |
±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
60 s |
Probes
Flue gas probes
Order Number: 0600 9740
Order Number: 0554 1208
Further probes
Temperature probes
Order Number: 0554 1208
Accessories
Accessories
Order Number: 0554 1203