The future of flue gas analysis has arrived with our comprehensive advanced analyser for the domestic and commercial heating engineer. The testo 330-1 LL Flue Gas Analyser (Pro Set with Printer) allows you to carry out your service and maintenance inspections quickly and efficiently. The high-quality analyser combines sophisticated sensor technology as well as a high level of safety with a long product life span and easy handling. The testo 330-1 LL comes with high-quality O2 and CO sensors and is TÜV-tested according to EN 50379, Parts 1-3 and 1st BImSchV.
testo 330-1 LL - Flue Gas Analyser (Pro set with printer)
Order-Nr. 0563 3371 71
Details
Product Description
Overview
The future of flue gas analysis has arrived with our comprehensive advanced analyser for the domestic and commercial heating engineer. The testo 330-1 LL Flue Gas Analyser (Pro Set with Printer) allows you to carry out your service and maintenance inspections quickly and efficiently. The high-quality analyser combines sophisticated sensor technology as well as a high level of safety with a long product life span and easy handling. The testo 330-1 LL comes with high-quality O2 and CO sensors and is TÜV-tested according to EN 50379, Parts 1-3 and 1st BImSchV.The Flue Gas Analyser Set at a glance:
- Two high-quality sensors for O2 and CO (without H2 compensation)
- Ambient CO measurement with 15-minute mean value calculation through standard flue gas probe
- Bigger savings with long-life (LL) sensors. Because the O2 and CO sensors need to be replaced less often (typically once every six years and therefore once less) you save on costs
- High-resolution graphic colour display, graphic presentation of the course of the measurement with flue gas matrix and line diagram
- Integrated sensor monitoring, traffic light colour coding system and at-a-glance status
- Logger function for up to two hours of continuous measurements
- Supersize memory for up to 500,000 readings
- Flue gas probe connector for quick, easy and safe probe attachment
- Infrared Printer included (0554 0549) for data printout directly at the measuring location
- Integrated magnets that stick to almost any metal object for easy measuring
- Easy-to-empty condensate collection tank
- ÜV-tested according to 1st BImSchV EN 50379, Parts 1-3
- Ambient CO / CO2 measurement (with optional Ambient CO probe 0632 3331, CO2 probe 0632 1240 + Connection Cable 0430 0143)
- Gas leak detection (with optional Gas leak detection probe 0632 3330)
- Gas flow and static gas pressure (with optional pressure connection set 0554 1203)
- Performance of gas tightness tests from -300 to +300 mbar with optional pressure connection set (0554 1203) + Gas Pressure Controller (300602 3000)
- Optional sensor upgrade (0554 2151) for NO and calculated NOx measurements
- Differential temperature measurement with optional differential temperature set (0554 1208)
- Optional CPA1 Accessories Kit (300554 1000) Includes: B2 angled probe, B1 gas cooker probe, hose connector, silicon hose, gas pressure controller, gas leak detector
Delivery Scope
testo 330-1 LL - Flue Gas Analyser with long-life gas sensors, rechargeable battery, mains charging unit (0554 1096), calibration protocol, graphic display, Flue gas probe (180mm x 6mm), carry case, testo infrared printer (0554 0549) and 6 x rolls of printer paper.
Further Versions:- testo 330-1 LL - Flue Gas Analyser (Pro set without printer) (0563 3371 70)
Technical Data
General technical data | |
---|---|
Weight |
600 g (without rechargeable battery) |
Dimensions |
270 x 90 x 65 mm |
Operating temperature |
-5 to +45 °C |
Protection class |
IP40 |
Display size |
240 x 320 pixels |
Display function |
Colour graphic display |
Power supply |
Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A |
Maximum memory |
500,000 readings |
Storage temperature |
-20 to +50 °C |
Differential Pressure - Piezoresistive | |
---|---|
Measuring range |
±10000 Pa |
Accuracy |
±0.3 Pa (0 to 999.00 Pa) plus ±1 Digit ±3 % of mv (10 to 10000 Pa) plus ±1 Digit |
Flue gas O₂ | |
---|---|
Measuring range |
0 to 21 Vol.% |
Accuracy |
±0.2 Vol.% |
Resolution |
±0.1 Vol.% |
Reaction time t₉₀ |
< 20 s |
Flue gas CO (with H₂-compensation) | |
---|---|
Measuring range |
0 to 8000 ppm |
Accuracy |
±10 ppm or ±10 % of mv (0 to 200 ppm) ±20 ppm or ±5 % of mv (201 to 2000 ppm) ±10 % of mv (2001 to 8000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 60 s |
Measuring rate |
0 to 500 ppm |
Flue gas COlow (with H₂-compensation) | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±2 ppm (0 to 399.0 ppm) ±5 % of mv (40 to 500 ppm) |
Resolution |
0.1 ppm |
Reaction time t₉₀ |
< 40 s |
Flue gas NO | |
---|---|
Measuring range |
0 to 3000 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (101 to 2000 ppm) ±10 % of mv (2001 to 3000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 30 s |
Flue gas Nolow | |
---|---|
Measuring range |
0 to 300 ppm |
Accuracy |
±2 ppm (0 to 39.9 ppm) ±5 % of mv (40 to 300 ppm) |
Resolution |
0.1 ppm |
Reaction time t₉₀ |
< 30 s |
Differential Pressure flue gas Draught - Piezoresistive | |
---|---|
Measuring range |
-9.99 to +40 hPa |
Accuracy |
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±1.5 % of mv (+3.01 to +40.00 hPa) |
Resolution |
0.01 hPa |
Temperature | |
---|---|
Measuring range |
-40 to +1200 °C |
Accuracy |
±5.0 °C (0 to +100.0 °C) ±0.5 % of mv (Remaining Range) |
Resolution |
0.1 °C (-40 to +999.9 °C) 1 °C (> +1000 °C) |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range |
0 to 120 % |
Resolution |
0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range |
0 to 99.9 % |
Resolution |
0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range |
0 to CO₂ max (Display range) |
Accuracy |
±0.2 Vol.% |
Resolution |
±0.1 Vol.% |
Reaction time t₉₀ |
< 40 s |
Velocity / Volume flow | |
---|---|
Measuring range |
0.15 to 3 m/s |
Resolution |
0.1 m/s |
Pressure measurement | |
---|---|
Measuring range |
0 to +300 hPa |
Accuracy |
±0.5 hPa (0.0 to 50.0 hPa) ±1 % of mv (50.1 to 100.0 hPa) ±15.0 % of mv (Remaining Range) |
Resolution |
0.1 hPa |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range |
0 to 4000 ppm |
Accuracy |
±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 60 s |
Ambient CO | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5 % of mv (> 100 ppm) |
Resolution |
1 ppm |
Reaction time |
Approx. 35 s |
with CO probe
Ambient CO₂ | |
---|---|
Measuring range |
0 to 1 Vol.% 0 to 10000 ppm |
Accuracy |
±50 ppm or ±2 % of mv (0 to 5000 ppm) ±100 ppm or ±3 % of mv (5001 to 10000 ppm) |
Reaction time |
Approx. 35 s |
with ambient CO₂ probe
Gas leak measurement for combustible gases (via gas leak detection probe) | |
---|---|
Measuring range |
0 to 10000 ppm CH₄ / C₃H₈; Display range |
Accuracy |
Signal optical display (LED) audible signal via buzzer |
Reaction time t₉₀ |
< 2 s |
with gas leak detection probe
Temperature (via the fine pressure probe) | |
---|---|
Measuring range |
-40 to +1200 °C max. (dependent on probe) |
Accuracy |
±0.5 °C (-40 to 100 °C) ±0.5 % of mv (Remaining Range) plus probe accuracy |
Resolution |
0.1 °C |
Downloads
Software
-
Testo ZIV driver ZIV 2000 for testo 320 and testo 330 (ZIP, 8.8 MB) Testo ZIV driver in the 2000 version. The Testo ZIV driver is used to connect the testo 320 and testo 330 measuring instruments to an application program (sweeping district administration program) according to the interface Version 2.0 defined by the Zentralverband des Schornsteinfegerhandwerks (Central Association of Chimney Sweeps, ZIV). Please check with the manufacturer of your application program as to whether this interface is supported. If Microsoft .NET Framework 4.0 has not been installed on the computer, it must be downloaded from the Microsoft website and installed on the system.