Saveris T3 D - 2-channel temperature radio probe, including display

Order-Nr.  0572 9262

  • Large measurement data memory

  • Flexible wireless data transfer

  • Large measuring range (-200 to +1760 °C)

  • Choice of TC characteristics

Temperature recorder 2 external TCs, with display, radio frequency 2.4 GHz


Details

Product Description

The temperature often has to be monitored and recorded at two points at the same time. With two connections for external thermocouple probes (TC Type K, Type T, Type J, Type S), the testo Saveris T3 D radio probe is ideally suited for this task. The TC characteristics can be freely selected. The large measuring range makes the radio probe universally applicable. The testo Saveris T3 D radio probe has a data memory for 6,000 readings per channel.

The T3 D radio probe is also equipped with a display, showing the current measurement data, battery status, limit value violations and quality of the radio link.

Please note: Saveris converter V 2.0 (order no. 0572 0258) is required for integrating Saveris radio probes into systems with base firmware V 1.X. For more information please contact your Testo partner.

What's inculded

testo Saveris T3 D, 2-channel radio probe with 2 external TC probe connections and display, radio frequency 2.4 GHz, including wall bracket, calibration protocol and 4 × AA alkaline manganese batteries.

Delivery Scope

testo Saveris T3 D, 2-channel radio probe with 2 external TC probe connections and display, radio frequency 2.4 GHz, including wall bracket, calibration protocol and 4 × AA alkaline manganese batteries.


Technical Data

General technical data

Weight

8 oz. / 240 g

Dimensions

3 x 3 x 1 in. / 80 x 85 x 38 mm

Operating temperature

-4.0° to 122.0 °F / -20 to +50 °C

Protection class

IP54

Housing

Plastic

Radio frequency

2.4 MHz

Transmission distance

approx. 100 m without obstruction at a frequency of 2.4 GHz

Wall bracket

included

Measuring rate

Standard 15 min, 1 min to 24 h can be set

Battery type

4 x AA batteries

Battery life

Battery life at +25 °C, 3 years; for freezer applications, 3 years with L91 Photo lithium Energizer batteries

Connection

2 TCs via TC socket, max. difference in potential 2 V

Display type

LCD

Display size

2 lines

Display function

7-segment with symbols

Memory

6,000 measurement values / channel

Storage temperature

-40.0° to 131.0 °F (incl. batteries) / -40 to +55 °C (incl. batteries)

Temperature - Type K TC

Measuring range

-319.0° to 2462.0 °F / -195 to +1350 °C

Accuracy

±0.9 °F or 0.5 % of mv / ±0.5 °C or 0.5 % of mv

Resolution

0.1 °F /TC type S 1 °F / 0.1 °C/TC type S 1 °C

Temperature - TC Type T (Cu-CuNi)

Measuring range

-328.0° to 752.0 °F / -200 to +400 °C

Accuracy

±0.9 °F or 0.5 % of mv / ±0.5 °C or 0.5 % of mv

Resolution

0.1 °F /TC type S 1 °F / 0.1 °C/TC type S 1 °C

Temperature - Type J TC

Measuring range

-148.0° to 1382.0 °F / -100 to +750 °C

Accuracy

±0.9 °F or 0.5 % of mv / ±0.5 °C or 0.5 % of mv

Resolution

0.1 °F /TC type S 1 °F / 0.1 °C/TC type S 1 °C

Temperature - TC Type S (Pt10Rh-Pt)

Measuring range

32.0° to 3200.0 °F / 0 to +1760 °C

Accuracy

±0.9 °F or 0.5 % of mv / ±0.5 °C or 0.5 % of mv

Resolution

0.1 °F /TC type S 1 °F / 0.1 °C/TC type S 1 °C