testo 330-1 LX - Commercial combustion analyzer kit 2 with printer

Order-Nr.  0563 3371 75

  • Field replaceable, pre-calibrated, long life sensors (up to six years)

  • High resolution, graphic color display

  • Intuitive interface

  • Upgradable accessories

The testo 330-1 LX combustion analyzer has a full color graphic display, which allows you to visualize flue gas measurement data clearly.  This high quality flue gas analyzer combines field replaceable, pre-calibrated sensor technology, a high level of safety, a long product life span, and easy handling.

Product Description

This testo 330-1 LX combustion analyzer kit with printer has easy to read graphical curves, easy to understand symbols, and a clear color display.  The pre-calibrated sensors allow you to begin your measurements without wasting any time.
 
  • Graphical readouts display either "in the green" or "in the red," which allows for fine tuning to ensure optimal efficiency
  • Large memory for up to 500,000 readings
  • Long lasting, user-changeable, pre-calibrated sensors that are easily replaceable
  • Quick and accurate measurements of O2, CO (up to 30,000 ppm with Standard Dilution System), NOx, °F, pressure, efficiency, and excess air

 

Delivery Scope

testo 330-1 LX combustion analyzer, 12" flue gas probe with 7' hose, IrDA printer (0554 0549), additional thermal paper rolls (6), extra particulate filters (10), AC power supply, rechargeable battery, certificate of conformity, and case
Differential Pressure

Measuring range

±40 InH₂O / ±10000 Pa

Accuracy

±0.0 InH₂O (0 to 0.04 InH₂O) plus ±1 Digit / ±0.3 Pa (0 to 9.99 Pa) plus ±1 Digit

±3.0 % of mv (0 to 40.00 InH₂O) plus ±1 Digit / ±3.0 % of mv (10 to 10000.00 Pa) plus ±1 Digit

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 20 sec

Flue gas CO

Measuring range

0 to 8000 ppm

Accuracy

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 8000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

*with optional H₂-compensation

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 500 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 40 sec

Flue Gas NO

Measuring range

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 30 sec

Flue gas NOlow

Measuring range

0 to 300 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 300 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 30 sec

Flue Gas Draft

Measuring range

-4.00 to +16 InH₂O / -9.99 to +40 hPa

Accuracy

±0.01 InH₂O or ±5 % of mv (-0.20 to +0.24 InH₂O) / ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.01 InH₂O (+0.24 to +1.20 InH₂O) / ±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+1.20 to +16.00 InH₂O) / ±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.00 InH₂O / 0.01 hPa

Temperature

Measuring range

-40° to 2192 °F / -40 to +1200 °C

Accuracy

±1 °F (32° to 212.0 °F) / ±0.5 °C (0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °F (-40° to 1831.8 °F) / 0.1 °C (-40 to +999.9 °C)

1.0 °F (> +1832 °F) / 1 °C (> +1000 °C)

Efficiency (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue Gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue Gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 sec

Velocity / Volume flow

Measuring range

29.50 to 591 fpm / 0.15 to 3 m/s

Resolution

0.1 fpm / 0.1 m/s

Flue gas CO (without H₂-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

Ambient CO

Measuring range

0 to 500 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (> 100 ppm)

Resolution

1 ppm

Reaction time

Approx. 35 sec

with CO probe

Ambient CO₂

Measuring range

0 to 1 Vol.%

0 to 10000 ppm

Accuracy

±50 ppm or ±2 % of mv (0 to 5000 ppm)

±100 ppm or ±3 % of mv (5001 to 10000 ppm)

Reaction time

Approx. 35 sec

with ambient CO₂ probe

Gas leak measurement for combustible gases (via gas leak detection probe)

Measuring range

0 to 10000 ppm CH₄ / C₃H₈; Display range

Accuracy

Signal optical display (LED) audible signal via buzzer

Reaction time t₉₀

< 2 sec

with gas leak detection probe

Temperature (via the fine pressure probe)

Measuring range

-40° to 2192 °F / -40 to +1200 °C max. (dependent on probe)

Accuracy

±1 °F (-40° to 212 °F) / ±0.5 °C (-40 to 100 °C)

±0.5 % of mv (Remaining Range) plus probe accuracy

Resolution

0.1 °F / 0.1 °C

General technical data

Dimensions

11 x 4 x 3 in. / 270 x 90 x 65 mm

Operating temperature

23° to 113 °F / -5 to +45 °C

Warranty

Instrument: 48 months; Probe: 48 months; Gas sensors (O₂, CO) 48 months; NO sensor 24 months; COlow sensor 24 months; Thermocouple 12 months; rechargeable battery: 12 months

Display size

240 x 320 pixels

Display function

Colour graphic display

Power supply

Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A

Maximum

500,000 readings

Storage temperature

-4° to 122 °F / -20 to +50 °C

Weight

21 oz. (without rechargeable battery) / 600 g (without rechargeable battery)

Probes

Connection cable

Order Number: 0430 0143

Mini ambient air probe

Order Number: 0600 3692

Temperature

Measuring range

32° to 176 °F / 0 to +80 °C

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Resolution

0.1 °F (32.0° to 212.0 °F) / 0.1 °C (0 to +100 °C)

Reaction time

30 sec

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Resolution

0.1 °F (33.8° to 212 {#0.0} °F) / 0.1 °C (1 to 100 {+#0} °C)

Reaction time

30 sec

Quick-action surface probe

Order Number: 0604 0194

Ambient CO₂

Measuring range

0 to +1 Vol.%

0 to +10000 ppm

Accuracy

±(75 ppm + 3 % of mv) (0 to +5000 ppm)

±(150 ppm + 5 % of mv) (+5001 to +10000 ppm)

Gas leak probe

Order Number: 0632 3330

Ambient CO probe

Order Number: 0632 3331

Ambient CO

Measuring range

0 to +500 ppm

Accuracy

±5 ppm (0 to +100 ppm)

±5 % of mv (+100.1 to +500 ppm)

Fine pressure probe

Order Number: 0638 0330

Temperature - Type K TC

Measuring range

Depends on probe, max. -40.0° to 2192.0 °F / Depends on probe, max. -40 to +1200 °C

-328.0° to 572.0 °F (with surface probe 0604 0994 (accessory)) / -200 to +300 °C (with surface probe 0604 0994 (accessory))

Accuracy

±0.9 °F (-40° to 212.0 °F) / ±0.5 °C (-40 to +100 °C)

±0.5 % of mv (Remaining Range) additionally ±1 digit, additionally accuracy of probe

Resolution

0.1 °F / 0.1 °C

Measuring rate

max. 1 / sec

Differential Pressure

Measuring range

-40.0 to +40.0 InH₂O / -9999.9 to +9999.9 Pa

Accuracy

±0.0 InH₂O (0 to +0.04 InH₂O) / ±0.3 Pa (0 to +9.99 Pa)

±3 % of mv (+0.04 to +40.0 InH₂O) additionally ±1 digit / ±3 % of mv (+10.00 to +9999.9 Pa) additionally ±1 digit

Resolution

0.01 InH₂O (-0.60° to 0.60 InH₂O) / 0.01 Pa (-149.99 to +149.99 Pa)

0.1 InH₂O (Remaining Range) / 0.1 Pa (Remaining Range)

Measuring rate

max. 1 / sec

Velocity / Volume flow

Measuring range

Display range: 29.50 to 591 fpm / Display range: 0.15 to 3 m/s

Resolution

0.1 fpm / 0.1 m/s

Instruments / options

Fine pressure probe

Order Number: 0638 0330

Measurement cells

Product Brochures

Manuals

Software