testo 330-1 LX - Commercial combustion analyzer kit 4 with printer and NOx measurement

Order-Nr.  400563 3304

  • Upgraded high-range 0 – 3,000 ppm NO module (1 ppm resolution) for many testing options

  • Field-replaceable, pre-calibrated, long life sensors (up to six years)

  • High-resolution graphic color display

  • Flue gas analyzer with onboard self-diagnostics

This testo 330-1 LX combustion analyzer printer kit has a full color graphic display, allowing the user to visualize flue gas measurement data graphically.  It has field-replaceable, pre-calibrated sensor technology for a long product life, and includes a high-range 0 – 3,000 ppm NO module, with a resolution of 1 ppm, allowing for many flue gas testing options.

Product Description

This testo 330-1 LX combustion analyzer printer kit has easy to read graphical curves, easy to understand symbols, and a clear color display.  It includes an upgraded high-range 0 – 3,000 ppm NO module with 1 ppm resolution, for a wider range of testing options.  The pre-calibrated sensors allow you to begin your measurements, without wasting  any time.
 
  • Graphical readouts display either "in the green" or "in the red," which allows adjustments that can be made for optimal efficiency
  • Large memory for up to 500,000 readings
  • Long lasting, user-changeable, pre-calibrated sensors that are easily replaceable
  • Quick and accurate measurements of O2, CO (up to 30,000 ppm with Standard Dilution System), NOx, temperature, pressure, efficiency, and excess air

 

Delivery Scope

testo 330-1 LX combustion analyzer with NO upgrade module, 12" flue gas probe with 7' hose, IrDA printer (0554 0549), additional thermal paper rolls (6), extra particulate filters (10), AC power supply, rechargeable battery, certificate of conformity, and case
Differential Pressure

Measuring range

±40 InH₂O / ±10000 Pa

Accuracy

±0.0 InH₂O (0 to 0.04 InH₂O) plus ±1 Digit / ±0.3 Pa (0 to 9.99 Pa) plus ±1 Digit

±3 % of mv (0 to 40 InH₂O) plus ±1 Digit / ±3 % of mv (10 to 10000 Pa) plus ±1 Digit

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

n1{#0.0} {%S1}

Reaction time t₉₀

< 20 sec

Flue gas CO

Measuring range

0 to 8000 ppm

Accuracy

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 8000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

Measuring rate

0 to 500 ppm

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 ppm (40 to 500 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 40 sec

Flue Gas NO

Measuring range

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 30 sec

Flue gas NOlow

Measuring range

0 to 300 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 ppm (40 to 300 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 30 sec

Flue Gas Draft

Measuring range

-4.00 to +16 InH₂O / -9.99 to +40 hPa

Accuracy

±0.01 InH₂O or ±5 % of mv (-0.20 to +0.24 InH₂O) / ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.01 InH₂O (+0.24 to +1.20 InH₂O) / ±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+1.20 to +16.00 InH₂O) / ±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.01 InH₂O / 0.01 hPa

Temperature

Measuring range

-40° to 2192 °F / -40 to +1200 °C

Accuracy

±0.9 °F (32° to 212.0 °F) / ±0.5 °C (0 to +100.0 °C)

±0.5 % of mv

Resolution

0.1 °F (-40° to 1831.8 °F) / 0.1 °C (-40 to +999.9 °C)

1.0 °F (> +1832 °F) / 1 °C (> +1000 °C)

Efficiency (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue Gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue Gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 sec

Velocity / Volume flow

Measuring range

29.53 to 591 fpm / 0.15 to 3 m/s

Resolution

0.1 fpm / 0.1 m/s

Pressure measurement

Measuring range

0 to +120 InH₂O / 0 to +300 hPa

Accuracy

±0.2 InH₂O (0.0 to 20.0 InH₂O) / ±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (20.0 to 40.0 InH₂O) / ±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 InH₂O / 0.1 hPa

Flue gas CO (without H₂-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

Ambient CO

Measuring range

0 to 500 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (> 100 ppm)

Resolution

1 ppm

Reaction time

Approx. 35 sec

with CO probe

Ambient CO₂

Measuring range

0 to 1 Vol.%

0 to 10000 ppm

Accuracy

±50 ppm or ±2 % of mv (0 to 5000 ppm)

±100 ppm or ±3 % of mv (5001 to 10000 ppm)

Reaction time

Approx. 35 sec

with ambient CO₂ probe

Gas leak measurement for combustible gases (via gas leak detection probe)

Measuring range

0 to 10000 ppm CH₄ / C₃H₈; Display range

Accuracy

Signal optical display (LED) audible signal via buzzer

Reaction time t₉₀

< 2 sec

with gas leak detection probe

Temperature (via the fine pressure probe)

Measuring range

-40 to +2192 °F max. (dependent on probe) / -40 to +1200 °C max. (dependent on probe)

Accuracy

±0.9 °F (-40° to 212 °F) / ±0.5 °C (-40 to 100 °C)

±0.5 % of mv (Remaining Range) plus probe accuracy

Resolution

0.1° °F / 0.1 °C

General technical data

Dimensions

11 x +4 in. / 270 x +90 mm

Operating temperature

23° to 113 °F / -5 to +45 °C

Display size

240 x 320 pixels

Display function

Color graphic display

Power supply

Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A

Maximum

500,000 readings

Storage temperature

-4° to 122 °F

Weight

21 oz. (without rechargeable battery) / 600 g (without rechargeable battery)

Instruments / options

Retrofit BLUETOOTH® interface

Order Number: 0450 3338

Fine pressure probe

Order Number: 0638 0330

Measurement cells

Product Brochures

Manuals

Software