testo 330i - flue gas analyzer

Order-Nr.  0632 3000 70

  • On-site digital creation of reports with the testo 330i App

  • Operation independent of measuring location – readings are always available when you need them

  • testoFix probe holder (optional) – holds the probe in the centre of flow at all times

  • Particularly robust, completely enclosed plastic housing

Proven technology meets revolutionary operation. The testo 330i flue gas analyzer was specifically developed to help you to overcome all the obstacles you meet when servicing and commissioning heating systems.  

Product Description

The testo 330i flue gas analyzer is an advancement of the testo 330 LL flue gas analyzer. Its proven measuring technology is once again at the heart of the testo 330i. This means that you can rely on highly accurate results when measuring flue gas, draught and O2 supply air. The testo 330i also has the following impressive features:
  • User-replaceable long-life sensors with a service life of up to 6 years
  • Successful TÜV inspection according to the 1st German Federal Immission Control Ordinance (BImSchV) and EN 50379, Parts 1-3
  • ntegrated draught and gas zeroing. This means that the probe does not have to be removed from the flue gas duct for the zeroing
  • Fresh air dilution up to 30,000 ppm upon exceeding a CO threshold value
The new testoFix probe holder is available as an accessory, so the flue gas probe is guaranteed not to lose the centre of flow once it has been found. This can be attached to the pipe quickly and easily. It holds the probe in the centre of flow and also serves as a fall-proof suspension system for the testo 330i flue gas analyzer. Incidentally, the hose between probe and measuring instrument is lighter and more flexible than before.

The future of flue gas measuring technology

The testo 330i no longer has a display. How do you make the correct adjustments to the flue gas analyzer? Where can you view the readings? What about the creation of measurement protocols? Via the testo 330i App on your smartphone. The readings are transferred from the testo 330i flue gas analyzer to the App via Bluetooth. So you always have the relevant values to hand whenever you need them. This is particularly useful when faced with larger systems or awkward measuring points as there is no need to look around corners, which can be annoying. The measurement parameters can also be set intuitively, via the App. Once you have completed the measurement, you can add comments or photos of the system to the results on site, and send them to your customer or the office via e-mail.

Requirement: iOS 7.1 / Android 4.3 or newer. Mobile end device with Bluetooth 4.0.

 

Delivery Scope

testo 330i flue gas analyzer with long-life gas sensors, 3 slots and integrated draught and gas zeroing, including O2/CO measuring cell, rechargeable battery and calibration protocol.  
Differential Pressure - Piezoresistive

Measuring range

0 to 300 hPa

Accuracy

±0.5 hPa (0.0 to +50.0 hPa)

±1 % of mv (+50.1 to +100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 hPa

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

CO determination (without H₂-compensation), automatic dilution in testo 320-2 LL

Measuring range

0 to 15000 ppm

Accuracy

±200 ppm or ±20 % of mv (0 to 15000 ppm)

Resolution

1 ppm

Flue gas NO

Measuring range

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

Option

Flue gas NO

Measuring range

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

Option

Flue gas Draught

Measuring range

-9.99 to +40 hPa

Accuracy

±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa

±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.01 hPa

Flue gas Draught

Measuring range

-9.99 to +40 hPa

Accuracy

±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.01 hPa

Temperature

Measuring range

-40 to +1200 °C

Accuracy

±0.5 °C (0.0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °C (-40 t1 +999.9 °C)

1 °C (Remaining Range)

dependent on the thermocouple

Temperature

Measuring range

-40 to +1200 °C

Accuracy

±0.5 °C (0.0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °C (-40 to +999.9 °C)

1 °C (Remaining Range)

dependent on the thermocouple

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue gas CO₂ calculation (calculated from O₂)

Measuring range

Display range 0 to CO₂ max

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Flue gas CO₂ calculation (calculated from O₂)

Measuring range

Display range 0 to CO₂ max

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Flue gas CO (without H₂-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm or ±10 % of mv (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

General technical data

Dimensions

270 x 160 x 57 mm

Operating temperature

-5 to +45 °C

Power supply

Rech. batt. block 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A (optional)

System requirements

requires iOS 7.1 or newer; requires Android 4.3 or newer; requires mobile end device with Bluetooth 4.0

Maximum memory

500000 readings

Storage temperature

-20 to +50 °C

Weight

720 g (excluding battery)

Combustion air / temperature

ZAR 1 933.25
excl. VAT

Product sets

testo 330i – flue gas set 

Order Number: 0563 3000 70

Price on Request
 

Order Number: 0563 3000 71

Price on Request

Accessories

USB connection cable

Order Number: 0449 0047

ZAR 366.30
excl. VAT
Spare battery 2600 mA

Order Number: 0515 0107

ZAR 447.70
excl. VAT
ZAR 3 215.30
excl. VAT
ZAR 10 907.60
excl. VAT
testoFix probe holder

Order Number: 0554 3006

ZAR 997.15
excl. VAT

Accessories for measuring instrument

Spare particle filter, 10 off

Order Number: 0554 3385

ZAR 386.65
excl. VAT

Flue gas analysis and flue gas measurement

The testo 330i flue gas analyzer features two user-replaceable long-life sensors for measuring O2 and CO. An NO sensor can be added optionally. Flue gas and draught can be measured in parallel using the testo 330i – so you can see all the key values simultaneously in the testo 330i App on your smartphone or tablet.

O2 supply air measurement

In balanced flue systems, is there perhaps a leak in the flue gas system? Use the testo 330i flue gas analyzer to find out: simply measure the O2 content of the combustion air in the dual wall clearance. This way, you can ensure that no flue gas is getting into the combustion air supply. This prevents damage due to condensate or impairment of the combustion process.

Differential pressure measurement

Measure the gas flow and gas resting pressure on gas boilers to ensure that the system can be commissioned properly. You can also use the data specified by the manufacturer for the nozzle pressure to tailor the appliance output to the actual heat requirement.

Product Brochures

Manuals

Software

  • Firmware testo 330i   (v2.10, BIN, 3.6 MB) It is partially not possible to execute a firmware update with Windows 8.1 / Windows 10. This can be solved by installing a new Bootloader once.
    A description and all necessary files can be found under Update-Kit / Bootloader

  • Update-Kit / Bootloader  (EXE, 380 KB) It is partially not possible to execute a firmware update with Windows 8.1 / Windows 10. This can be solved by installing a new Bootloader once.
    A description and all necessary files can be found under Update-Kit / Bootloader

  • Testo ZIV driver ZIV 2000 for testo 320 and testo 330  (ZIP, 8.8 MB) Testo ZIV driver in the 2000 version. The Testo ZIV driver is used to connect the testo 320 and testo 330 measuring instruments to an application program (sweeping district administration program) according to the interface Version 2.0 defined by the Zentralverband des Schornsteinfegerhandwerks (Central Association of Chimney Sweeps, ZIV). Please check with the manufacturer of your application program as to whether this interface is supported. If Microsoft .NET Framework 4.0 has not been installed on the computer, it must be downloaded from the Microsoft website and installed on the system.

  • Testo ZIV driver for testo 320 and testo 330   (v2.1, EXE, 64.193 KB) The Testo ZIV driver is used to connect the testo 320 and testo 330 measuring instruments to an application program (sweeping district administration program) according to the interface defined by the Zentralverband des Schornsteinfegerhandwerks (ZIV, Central Association of Chimney Sweeps) in version 1.0 of 01. August 2012 as well as in version 2.0 of 13. February 2017. Please check with the manufacturer of your application program as to whether this interface is supported.