1. Home
  2. testo  310 II

testo 310 II - Uređaj za analizu dimnih plinova

0563 3104
€ 590,00 € 737,50
  • Simultano, pojedinačno mjerenje i prikaz svih relevantnih mjernih parametara (O2, CO, CO2, temperatura dimnih plinova i okoline, CO u okolini, propuh i tlak). Zaslon koji se može konfigurirati putem testo Smart aplikacije
  • Simultana, dodatna mjerenja putem testo Smart aplikacije (npr. tlak protoka plina, temperatura protoka i povrata)
  • Jednostavno i intuitivno navođenje kroz izbornike
  • Digitalna dokumentacija, prijenos podataka i upravljanje podacima o kupcima putem testo Smart aplikacije
  • Monterima i tehničarima grijanja koji obavljaju puštanje u pogon i održavanje sustava tople vode i grijanja u stambenim zgradama potreban je pouzdan i stabilan mjerni instrument s kojim će lako obavljati svoje mjerne zadatke, poput analize ispušnih plinova. Novi testo 310 II pruža individualnu podršku za njihove dnevne zadatke mjerenja i olakšava njihov svakodnevni rad.

    Preciznost mjerenja, podesivi zaslon mjerenja, mogućnosti paralelnog mjerenja, intuitivan rad, čvrsto kućište, mogućnost povezivanja na testo Smart aplikaciju: Naš analizator dimnih plinova testo 310 II nudi sve što je potrebno instalaterima i tehničarima grijanja za praktičan rad na sustavima grijanja.
     
     

    Pouzdano ispitivanje sustava grijanja s analizatorom dimnih plinova testo 310 II for beginners

    . < P> Kompaktni analizator dimnih plinova nudi, uz jednostavno korisničko sučelje, navigaciju izbornicima s četiri integrirana mjerna izbornika za dimne plinove, propuh, ambijentalni CO i tlak. Svi rezultati mjerenja vidljivi su jednim pogledom na zaslonu i čak se mogu konfigurirati zahvaljujući grafičkom zaslonu visoke rezolucije.

    Ako je potrebno, ruke vam mogu biti slobodne tijekom mjerenja - jer se analizator dimnih plinova testo 310 II može pričvrstiti na metalne površine, npr. plamenik, pomoću magneta na stražnjoj strani instrumenta. Ali to nije jedina praktična značajka: Testo Smart aplikacija vam omogućuje upravljanje i konfiguriranje vašeg instrumenta putem daljinske funkcije.

    Robusna konstrukcija za oštra, prljava okruženja, brzo nuliranje senzora u 30 sekundi, lako zamjenjivi filtar sonde i separator kondenzata koji se može brzo isprazniti čine analizator dimnih plinova optimalnim alatom za mehaniku postrojenja jer je pametno dizajniran.

    Ako je potrebno, rezultati mjerenja mogu se prenijeti na opcijski dostupan Testo brzi pisač putem Bluetooth® sučelja ili poslati e-poštom i ispisati izravno na licu mjesta.

    Analizator dimnih plinova testo 310 II uklj. punjivu bateriju i kalibracijski protokol za mjerenje O2, CO, hPa i °C, sondu 180 mm s konusom, silikonsko crijevo za mjerenje tlaka, filtere čestica 5 kom. i kovčeg

    Temperature - TC Type K (NiCr-Ni)

    Measuring range
    −20 to +100 °C
    Accuracy
    ±1 °C
    Resolution
    0,1 °C
    Reaction time
    < 50 s
    Temperature (ambient temperature)

    Temperature - TC Type J (Fe-CuNi)

    Measuring range
    0 to +400 °C
    Accuracy
    ±1 °C (0 to +100 °C)
    ±1,5 % of mv (> 100 °C)
    Resolution
    0,1 °C
    Reaction time
    < 50 s
    Temperature (flue gas)

    Flue gas O₂

    Measuring range
    0 to 21 Vol.%
    Accuracy
    ±0,2 Vol.%
    Resolution
    0,1 Vol.%
    Reaction time t₉₀
    30 s

    Sets

  • Sets
    testo 310 II - analizator dimnih plinova s pisačem
      :
      0563 3105
      € 770,00 € 962,50
    • Accessories

    • Accessories
      Spare particle filter
      Spare particle filter, compact probe; 10 off
        :
        0554 0040
        € 29,00 € 36,25
      • Accessories
        Spare thermal paper
        Spare thermal paper for printer, permanent
          :
          0554 0568
          € 28,00 € 35,00
        • Accessories
          USB mains unit incl. cable
            :
            0554 1105
            € 43,00 € 53,75
          • Printer and accessories


            Draught measurement in the flue gas duct

            Draught measurement is actually a differential pressure measurement. This differential pressure occurs between two sub-areas as a result of a difference in temperature. This is turn generates a flow to compensate. In the case of flue gas systems, the difference in pressure is an indicator of the “chimney flue draught”. This is measured between the flue gas and ambient air at the measurement orifice at the core of the flue gas flow.

            To ensure the flue gases are safely transported through the chimney there must be a differential pressure (chimney flue draught) for boiler systems that work with low pressure.

            If the draught is permanently too high, the average flue gas temperature increases and therefore flue gas loss. The level of efficiency drops.

            If the draught is permanently too low, oxygen may be lacking during combustion, resulting in soot and carbon monoxide. This will also cause a drop in the level of efficiency.

            Ambient CO measurement in the heated environment

            Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon (oil, gas, and solid fuels, etc.). If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation. This is why it is necessary to regularly check CO emissions at the combustion points of heating systems, and places often frequented by people (in our case, where the combustion systems for hot water generation are), and in the surrounding areas.

            Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)

            The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:

            1. Ensuring the atmosphere is contaminated as little as possible by pollutants; and

            2. energy is used as efficiently as possible.

            Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded.

            Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.

            Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.

            Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)

            Standard readings taken during services of domestic heating systems include checking the gas pressure on the burners. This involves measuring the gas flow pressure and gas resting pressure. The flow pressure, also called supplied pressure, refers to the gas pressure of the flowing gas and resting pressure of the static gas. If the flow pressure for gas boilers is slightly outside the 18 to 25 mbar range, adjustments must not be made and the boiler must not be put into operation. If put into operation nonetheless, the burner will not be able to function properly, and explosions will occur when setting the flame and ultimately malfunctions; the burner will therefore fail and the heating system will shut down.