Technical Data
Temperature - NTC | |
---|---|
Measuring range |
−20 to +70 °C |
Accuracy |
±0,4 °C (−10 to +50 °C) ±0,5 °C (−20 to 10,1 °C) ±0,5 °C (+50,1 to +70 °C) |
Reaction time |
15 s |
Humidity - Capacitive | |
---|---|
Measuring range |
0 to +100 %RH |
Accuracy |
±2 %RH (+2 to +98 %RH) |
General technical data | |
---|---|
Length probe shaft |
250 mm |
Diameter probe shaft |
4 mm |