1. Home
  2. Applications
  3. testo 370 高精度红外烟气分析仪比对与测试

德图高温红外烟气分析仪

连续监测11组分气体

无惧水分,烟气组分无损失

超长运行时间

testo 370

testo 370 高精度红外烟气分析仪比对与测试

测试:2017年6月初在太原某冶炼厂,因为co浓度过高,对于电化学类仪器无法进行测量,红外原理仪器运行良好

CO[mg/m3]SO2[mg/m3]
testo 370CEMStesto 370CEMS
01.06.2017 12:08:001759.051678.699.157.95
01.06.2017 12:09:001700.371615.099.68.5
01.06.2017 12:10:001787.951866.5810.110.6
01.06.2017 12:11:002035.521952.9510.649.84
01.06.2017 12:12:002277.322196.6310.949.64
01.06.2017 12:13:002293.962373.5912.4413.64
01.06.2017 12:14:002286.042346.8913.7215.52
01.06.2017 12:15:002278.142232.1816.7918.49
01.06.2017 12:16:001354.031377.6322.9621.06

测试:2017年5月末在上海某厂测量焦化炉

CO[mg/m3]SO2[mg/m3]
testo 370CEMStesto 370CEMS
22.05.2017 13:50:0049.5350.0310.5512.67
22.05.2017 13:52:0017.7617.562.683.78
22.05.2017 13:53:00256.08253.5822.5218.83
22.05.2017 13:54:002217.332067.13112.1123.06
22.05.2017 13:55:001876.832016.83109.01119.75
22.05.2017 13:56:001228.931328.93104.58113.54
22.05.2017 13:57:00547.35607.3575.2769.61
22.05.2017 13:58:00125.71115.5935.7940.15
22.05.2017 13:59:0030.3735.695.938.23
22.05.2017 14:00:0016.9513.633.93.7
22.05.2017 14:01:00111.87121.918.1316.04
22.05.2017 14:02:00588.9649.352.4657.46
22.05.2017 14:03:001266.81367.3269.1674.98

测试:2017年5月初,在杭州某热电厂进行测量

SO2[mg/m3]NO2[mg/m3] NO[mg/m3] O2[Vol%]
testo 370CEMStesto 370CEMStesto 370CEMStesto 370CEMS
10.05.2017 11:35:250.040.257.845.4415.115.875.424.71
10.05.2017 11:35:450.120.259.645.4419.615.875.444.79
10.05.2017 11:36:040.19 0.2510.582.5922.1215.875.474.79
10.05.2017 11:36:240.220.2510.142.5922.0115.875.464.77
10.05.2017 11:36:430.210.259.22.5919.8315.875.434.76
10.05.2017 11:37:030.180.254.950.0117.315.875.454.73
10.05.2017 11:37:230.160.252.850.0119.8215.875.454.75
10.05.2017 11:37:420.140.251.820.0121.2215.875.454.78
10.05.2017 11:38:020.120.251.660.7722.4315.875.464.77
10.05.2017 11:38:210.110.251.80.7723.2615.875.474.76
10.05.2017 11:38:410.090.251.670.7723.4715.875.484.75
10.05.2017 11:39:000.080.251.653.4324.0615.875.474.77
10.05.2017 11:39:400.050.251.643.4324.915.875.454.67
10.05.2017 11:40:190.030.251.56 4.3824.8615.875.444.7

测试:2016年11月初,南京郊外某自备电厂

testo 370 为高温红外设备,避免了冷凝过程中的SO2吸附,测量值较现场CEMS更为精准。

testo 370 [mg/m3]CEMS [mg/m3]
Date TimeSO2SO2
01.11.2016 11:37:1918.3323.27
01.11.2016 11:38:2020.4423.27
01.11.2016 11:39:0120.8823.95
01.11.2016 11:40:0221.9423.95
01.11.2016 11:41:0423.1423.27
01.11.2016 11:42:0524.5123.27
01.11.2016 11:43:0725.3623.27
01.11.2016 11:44:0824.4823.27
01.11.2016 11:45:1025.5823.27

测试:2016年11月底,上海某热电厂,燃料为城市煤气

在CEMS出现负值时,t370保持了精准数值。

testo 370 [mg/m3]CEMS [mg/m3]
Date TimeSO2SO2
2016/11/24 15:572.07-0.31
2016/11/24 15:582.04-0.59
2016/11/24 15:592.04-0.82
2016/11/24 16:002.01-0.36
2016/11/24 16:014.64-0.11
2016/11/24 16:025.01 -0.28
2016/11/24 16:035.09-0.53
2016/11/24 16:040.86-0.19
2016/11/24 16:050.58-0.46
2016/11/24 16:060.55-0.93
2016/11/24 16:070.780.3
2016/11/24 16:081.240.5
2016/11/24 16:091.70.1
2016/11/24 16:102.241.19
2016/11/24 16:112.580.05
2016/11/24 16:123.120.9
2016/11/24 16:133.520.19
2016/11/24 16:143.890.83

测试:2016年11月底,上海某热电厂,燃料为城市煤气

testo 370 [mg/m3]CEMS [mg/m3]CEMS [mg/m3]
Date TimeNO2NONONO2NOx
2016/11/24 15:320.9940.73350.254.93
2016/11/24 15:330.8438.97340.447.12
2016/11/24 15:340.837.93340.438.24
2016/11/24 15:350.8938.13350.436.25
2016/11/24 15:360.9939.87310.436.67
2016/11/24 15:370.9940.49310.435.09
2016/11/24 15:380.9840.2528 0.432.97
2016/11/24 15:390.9738.67200.434.32
2016/11/24 15:401.0733.17210.235.32
2016/11/24 15:411.1430.7621030.95
2016/11/24 15:421.1628.4139030.96
2016/11/24 15:431.130.44400.226.2
2016/11/24 15:441.0737.89340.417.92
2016/11/24 15:451.0942.05360.419.34
2016/11/24 15:461.1641.41380.639.06
2016/11/24 15:471.2140.64390.641.4
2016/11/24 15:481.241.36380.641.77
2016/11/24 15:491.1742.3380.633.78
2016/11/24 15:501.1342.94360.637.02
2016/11/24 15:51 0.991.0542.7350.639.05

测试:2016年12月初,在上海某大学的实验室内,testo 370对工业淤泥脱水过程中排放的气体进行了测试,除了常规组分外,testo 370的CH4,NH3的多参数功能,为测试实验提供了技术支持。气体中含有的少量SO2成分,数据同时得到了testo 350烟气分析仪的佐证。

testo 370 [mg/m3]CEMS [mg/m3]
Date TimeCOSO2NO2NOCH4NH3COSO2
07.12.2016 15:15:080.581.64002.482.491.250.57
07.12.2016 15:16:090.591.59002.52.4400.86
07.12.2016 15:17:110.611.57002.52.3900.57
07.12.2016 15:18:120.641.57002.492.3300.57
07.12.2016 15:19:140.621.56002.512.270.57
07.12.2016 15:20:150.591.56002.532.211.250.86
07.12.2016 15:21:170.551.58002.532.181.250.57
07.12.2016 15:22:180.541.6002.532.1500.57
07.12.2016 15:23:200.531.6002.542.1300.57
07.12.2016 15:24:010.521.58002.582.121.250.86
07.12.2016 15:25:020.521.57002.62.11.250.57
07.12.2016 15:26:040.521.58002.572.11.250.86
07.12.2016 15:27:050.521.6002.542.1100.86
07.12.2016 15:28:070.551.63002.52 2.100.86
07.12.2016 15:29:080.591.63002.52 2.081.250.57
07.12.2016 15:30:090.611.66002.42.0100.86
07.12.2016 15:31:110.591.67002.42.0100.86
07.12.2016 15:32:120.561.69002.411.981.250.86
07.12.2016 15:33:140.551.7002.451.9600.86
07.12.2016 15:34:150.551.73002.441.941.250.57
07.12.2016 15:35:170.561.75002.41.921.250.57
07.12.2016 15:36:190.61.77002.391.891.250.57
07.12.2016 15:37:200.651.76002.471.8600.86
07.12.2016 15:38:010.71.76002.521.851.250.57
07.12.2016 15:39:020.721.77002.551.811.250.86
07.12.2016 15:40:040.711.81002.491.781.250.86

行业应用及新闻

testo 370 为氨逃逸保驾护航

了解更多

testo 370 解决垃圾焚烧厂测量问题

了解更多

使用德图 testo 370 高温红外烟气分析仪监测钢铁生产中的SO₂排放,无惧CO

了解更多

垃圾焚烧烟气污染物的排放测量,你需要注意什么?

了解更多