Thermal imaging cameras are mainly used to locate temperature anomalies quickly: thermal bridges in buildings, hotspots in electrical systems, overloaded maintenance components or defects in PV modules. Thermography is meaningful when the recording conditions suit the application and the results are documented reproducibly.
Typical fields of application include building thermography, electrical inspection, maintenance and predictive maintenance, HVAC/R diagnostics and photovoltaics. In all cases, thermography is particularly strong as a screening method: it shows where something is conspicuous and provides the basis for prioritization, follow-up measurement and documentation.
In buildings, thermography makes temperature distributions visible on surfaces, for example on exterior walls, ceiling connections, window reveals and pipe routes. Its benefit is that deviations can be identified quickly and checked in a targeted way instead of renovating without a clear diagnosis.
Typical questions are: Where is heat being lost? Where are thermal bridges? Where is a leak in the building envelope likely? Which areas show unusual cooling that could indicate moisture or a risk of mold? Measurement points are often connections, corners, transitions and surfaces with suspected insulation problems.
Meaningful building thermography requires suitable conditions. A sufficient temperature difference between inside and outside improves contrast, while wind and rain can cool surfaces and distort interpretation. Direct sunlight often causes heating effects that must not be confused with insulation quality. The measurement conditions should therefore always be documented.
Screening: locate conspicuous areas with a consistent scale and focus.
Verification: check suspected areas with suitable additional measurements, depending on the setup.
Documentation: name measurement points clearly and show them comparably with the same perspective, scale and distance.
During electrical inspections, thermography shows temperature differences at components, connections and cables. This is particularly useful because many problems first become visible as local heating, often before shutdowns or consequential damage occur.
Common causes include increased contact resistance at connections, uneven load distribution or thermally stressed components. A hotspot is an indication, not a diagnosis. The cause must be confirmed by visual inspection, measurement and, where necessary, maintenance.
The significance depends strongly on the load state: without a relevant load, critical points may remain inconspicuous. Safe access, measurement distance (IFOV) and reproducible recording conditions are also decisive. In control cabinets, comparability across points and time is often more useful than an absolutely correct temperature.
For recurring inspections, a standard is worthwhile: use the same measurement points and scale, document the distance and use clear names. This makes trends visible and allows actions to be prioritized.
In maintenance, thermography primarily supports rapid prioritization: which machine, bearing or drive is conspicuous and should be checked specifically during the next service?
Thermography is often used on motors, bearings, couplings, gearboxes, pumps and conveying equipment. The advantage is that measurements can be taken during operation without touching components.
Thermography becomes meaningful when a reference state, such as normal operation, is defined and measurements are repeated under similar conditions. This reduces misinterpretation caused by changing loads, ambient heat or seasonal effects.
In HVAC/R applications, thermography is especially useful for locating anomalies at components and distribution systems, such as uneven heating, unwanted heat losses or indications of malfunctions.
Typical tasks include assessing temperature distributions, finding leaks or insulation anomalies and quickly diagnosing heat exchangers and pipes.
For interpretation, remember that thermography measures surfaces. For insulated pipes, air temperatures or medium temperatures, additional measurements (contact, Smart Probes, and surface/penetration probes) are often needed to confirm the diagnosis.
For PV systems, thermography is a fast screening method for making hotspots and anomalies visible. It can provide indications of cell damage, contact problems or string anomalies.
Typical anomalies include locally overheated areas, uneven heating in module surfaces and conspicuous connection areas. Evaluation is ideally performed in the context of the system parameters.
Meaningful PV thermography depends strongly on irradiation and load state. Without sufficient irradiation, temperature contrasts are lower. Viewing angle, reflections such as the sky, and measurement distance/IFOV also affect the visibility of small defects.
In power plants, substations and distribution networks, thermography helps detect overheated contacts, terminals and busbars at an early stage. Defined load conditions and reproducible measurement points are important so that trends can be assessed reliably.
In production environments, thermography is used to monitor drives, bearings, conveying equipment, molds and tools during operation. Fixed measurement points and clear tolerance bands make it possible to integrate thermal behavior into predictive maintenance.
For facility management, thermography combines typical tasks from building thermography and HVAC/R. Anomalies in insulation, pipe networks, heating circuits and ventilation components become visible quickly. Regular, consistently structured rounds make deviations over time easier to identify.
Once you have narrowed down your application, the next steps are usually to deepen the relevant fundamentals (ε/RTC/IFOV), define a workflow with reproducible documentation and select a camera whose resolution and lens match the object size and distance.
We look forward to supporting you with our expertise and individual solutions.