1. Home
  2. Glossary
  3. Sound level meters: classification measurements the modern way

Sound level meter

Accurately measured decibels

Sound level meter from Testo

Sound level meters are designed to help measure the volume in decibels both in the workplace and at home. Just like temperature, noise is perceived subjectively. Anyone who complains about their loud neighbor feels disturbed by their house music: after measuring the actual volume in decibels, however, it often turns out that this subjective disturbance cannot be classified as noise. The sound level meter must also be used at the workplace to determine whether the employee requires special hearing protection or whether the existing volume is still reasonable and not harmful to health.

Sound level meters are used in the following areas:

  • in homes to determine the noise level from the surroundings

  • in building services

  • in air conditioning and ventilation technology

  • at workplaces in offices and on machines

Sound level meter

The ideal sound meter -
built precisely for your application

Sound level meters: Standard-compliant measurements for industry and trade

Sound level meter

The sound level meter is suitable for standard-compliant sound measurements and displays the measured values in decibels. A sound level meter is indispensable for employers in particular, as they must ensure that the working and immission protection conditions at the workplace are complied with. This takes account of occupational health and safety, which focuses on keeping employees healthy. Equally important is the measurement of decibels in combustion, heating and air conditioning systems, for which the testo 815 sound level meter is available, for example. The testo 816 sound level meter is also suitable for this purpose and is available as a non-compliant sound measuring instrument. It is always important to comply with the legal standards, which is only possible when using the tested sound level meters. Testo's sound level meters are based on the standard IEC 61672-1, which has been in force for several years. In contrast to the previous standard, it is geared towards higher accuracy. There are three accuracy classes, with testo sound level meters corresponding to class 2.

Sound meter: Important settings

The sound level meter measures the volume in decibels and thus provides the person taking the measurement with an objective value. However, it is important to make a few settings on the sound level meter in order to actually obtain usable results. For example, the time weighting must be set, which allows the device to react to sounds that change slowly or suddenly in volume. The frequency weighting must also be selected in order to determine the sound level in a linear or aurally accurate manner. The A characteristic curve, which is standardized, is used for aurally accurate assessment of the volume. It is precisely implemented by the testo sound level meters. Furthermore, it is of course important that the instrument's microphone is aligned with the noise source. Only if these settings are actually made can the noise meter capture the sound waves correctly and display the measurement result correctly in decibels.

Sound meter

DB measuring device: Observe limit values

When evaluating the measurement results in decibels, it is important to know what the law says and this sets certain limits for the volume. The reason: noise causes illnesses, the first of which is hearing loss. Once destroyed, hearing does not recover! Hearing loss is therefore at the top of the list of occupational diseases, as no subsequent improvements will help. It is therefore important to adhere to the specified values from the outset. The sound level meter is intended to help prevent damage to health and indicates when there are health concerns. Currently, 55 to 85 decibels are considered harmless to health, whereby the level of the guideline values depends on the type of workplace. In a production hall, 70 decibels is still considered the minimum value, but the same value would be far too loud for an open-plan office. There should be no more than 55 decibels, which is roughly equivalent to a conversation at a normal volume. However, to determine the exact value, a suitable sound level meter must be used.

DB measuring device

Customer Service
Eurotec Ltd
Unit C, 750 Great South Road
Penrose Auckland 1061
PO Box 14-543, Panmure, Auckland 1741New Zealand
+64 (0)9 579 1990sales@eurotec.co.nz


© 2026

Image