Image
  1. Home
  2. Globe probe Ø 150mm, TC Type K, for measuring radiant heat

Globe thermometer (TC type K) - for radiant heat

0602 0743
Globe probe Ø 150mm
Globe-Thermometer ~ 150 mm, TE Typ K, zum Messen der Strahlung
  • Standard-compliant measurements – Suitable for radiant heat measurement in line with ISO 7243, ISO 7726, DIN EN 27726 and DIN 33403.
  • Wide temperature range – Measures radiant heat from 0 to +120 °C for versatile application.
  • Precise thermocouple – Uses type K thermocouple for accurate and reliable temperature readings.
  • Ideal for workplace monitoring – Supports assessments of thermal comfort directly at employee workstations.
  • Durable construction – Hollow 150 mm sphere with integrated sensor designed for robust, long-term use.
  • Globe thermometer with type K thermocouple for precise measurement of radiant heat in accordance with recognised international and European standards.
    The globe thermometer from Testo is designed for the accurate and standard-compliant measurement of radiant heat – an essential parameter in determining thermal comfort in workplace environments. Meeting the requirements of ISO 7243, ISO 7726, DIN EN 27726 and DIN 33403, this instrument plays a key role in evaluating conditions that impact physical wellbeing and productivity.

    Equipped with a type K thermocouple at the centre of a 150 mm hollow sphere, the globe thermometer measures radiant temperature within a range of 0 to +120 °C. When used in conjunction with a suitable measuring instrument, it enables precise analysis of thermal radiation. A notable difference between ambient and globe temperatures can indicate high exposure to radiant sources, such as direct sunlight, prompting necessary adjustments to workplace conditions.

    This globe thermometer is a practical tool for professionals in occupational health, HVAC and indoor climate assessment, helping to ensure that workspaces remain comfortable and compliant with key comfort standards.

    Globe thermometer (Ø 150 mm, TC type K) with 1.45 m fixed cable.

    Temperature - TC Type K (NiCr-Ni)

    Measuring range
    0 to +120 °C
    Accuracy
    Class 1 ¹⁾
    1) According to standard EN 60584-1, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

    General technical data

    Weight
    385 g
    Dimensions
    250 x 150 x 150 mm
    Cable length
    1.4 m
    Emissivity
    0,95
    Probe head diameter
    150 mm
    Product colour
    Black