testo 330-1 LX - Commercial combustion analyzer kit 1

Order-Nr.  0563 3371 70

  • Field replaceable, pre-calibrated, long life sensors (up to six years)

  • High resolution, graphic color display

  • Intuitive interface

  • Upgradable accessories

The testo 330-1 LX combustion analyzer has a full color graphic display, which allows you to visualize flue gas measurement data clearly.  With field replaceable, pre-calibrated sensors, the testo 330-1 LX ensures a long product life, allowing for many flue gas testing options.

Product Description

This testo 330-1 LX flue gas analysis kit allows you to carry out your service and maintenance inspections quickly and efficiently.  This high quality combustion analyzer combines sophisticated sensor technology, a high level of safety, a long product life span, and easy handling.
 
  • Two high quality sensors for O2 and CO
  • Big savings with Long Life (LL) sensors (cells are typically replaced once every six years)
  • High resolution graphic color display
  • Integrated sensor monitoring, traffic light color coding system and at-a-glance status
  • User-changeable sensors, easy to replace sensor filter
  • Logger function for up to two hours of continuous measurements
  • Large memory for up to 500,000 readings
  • Integrated magnets that stick to almost any metal object for easy measuring
  • Easily emptied condensate collection tank
  • 4-year warranty without service contract

 

Delivery Scope

testo 330-1 LX combustion analyzer, 12" flue gas probe with 7’ hose, extra particulate filters (10), AC power supply, rechargeable battery, certificate of conformity, and case
Differential Pressure

Measuring range

0 to +120 InH₂O / 0 to +300 hPa

Accuracy

±0.2 InH₂O (0.0 to 20.0 InH₂O) / ±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (20.0 to 40.0 InH₂O) / ±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 InH₂O / 0.1 hPa

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 20 sec

Flue gas CO

Measuring range

0 to 8000 ppm

Accuracy

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 8000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

*with optional H₂-compensation

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 500 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 40 sec

Flue Gas NO

Measuring range

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 30 sec

Flue gas NOlow

Measuring range

0 to 300 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 300 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 30 sec

Flue Gas Draft

Measuring range

-4.00 to +16 InH₂O / -9.99 to +40 hPa

Accuracy

±0.01 InH₂O or ±5 % of mv (-0.50 to +0.24 InH₂O) / ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.01 InH₂O (+0.24 to +1.20 InH₂O) / ±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+3.01 to +16.00 InH₂O) / ±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.01 InH₂O / 0.01 hPa

Temperature

Measuring range

-40° to 2192 °F / -40 to +1200 °C *

Accuracy

±0.9 °F (32° to 212.0 °F) / ±0.5 °C (0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °F (-40° to 1831.8 °F) / 0.1 °C (-40 to +999.9 °C)

1.0 °F (> +1832 °F) / 1 °C (> +1000 °C)

* Measuring range depends on the connected flue gas probe

Efficiency (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue Gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue Gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 sec

Pressure measurement

Measuring range

0 to +120 InH₂O / 0 to +300 hPa

Accuracy

±0.2 InH₂O (0.0 to 20.0 InH₂O) / ±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (50.1 to 40.0 InH₂O) / ±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 InH₂O / 0.1 hPa

Flue gas CO (without H₂-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

Ambient CO

Measuring range

0 to 500 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (> 100 ppm)

Resolution

1 ppm

Reaction time

Approx. 35 sec

with CO probe 0632 3331

Ambient CO₂

Measuring range

0 to 1 Vol.%

0 to 10000 ppm

Accuracy

±75 ppm or ±3 % of mv (0 to 5000 ppm)

±150 ppm or ±5 % of mv (5001 to 10000 ppm)

Reaction time

Approx. 35 sec

with ambient CO₂ probe 0632 1240

Gas leak measurement for combustible gases (via gas leak detection probe)

Measuring range

0 to 10000 ppm CH₄ / C₃H₈; Display range

Accuracy

Signal optical display (LED) audible signal via buzzer

Reaction time t₉₀

< 2 sec

with gas leak detection probe 0632 3330

General technical data

Dimensions

11 x 4 x 3 in. / 270 x 90 x 65 mm

Operating temperature

23° to 113 °F / -5 to +45 °C

Protection class

IP40

Display size

240 x 320 pixels

Display function

Colour graphic display

Power supply

Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A

Maximum

500,000 readings

Storage temperature

-4° to 122 °F / -20 to +50 °C

Weight

21 oz. (without rechargeable battery) / 600 g (without rechargeable battery)

Instruments / options

Fine pressure probe

Order Number: 0638 0330

Measurement cells

Product Brochures

Manuals

Software