testo 330-2 LX - Industrial combustion analyzer kit 1

Order-Nr.  0563 3372 71

  • Long life sensors (up to six years) with over-range protection

  • Industrial CO range of 8,000 ppm (up to 30,000 ppm via onboard dilution)

  • Onboard instrument diagnostics and system leak check

  • Optional NOx sensor is field upgradable

The testo 330-2 LX combustion analyzer measures O2, CO (up to 30,000 ppm), temperature, pressure, and other required combustion efficiency parameters.  In addition, this flue gas analyzer has NOx upgradability, on-site printout capability, a large memory, and a graphic tuning chart to show ideal combustion efficiency.

Product Description

For commercial and industrial flue gas applications, the testo 330-2 LX combustion analyzer is properly outfitted with high range CO, sensor protection, a large memory for maintaining service records, on-site printing capability, and if needed, is easily field upgraded with a plug and play NOx sensor.  The interface for burner control modules makes this a versatile flue gas tuning and testing tool.  The testo 330-2 LX combustion analyzer has the longest sensor warranty on the market – 4 years!  Rugged construction and high quality sensors provide years of combustion efficiency, reliability, and a very low cost of ownership.
 
  • Built-on dilution systems allow for CO readings of up to 30,000 ppm
  • Onboard self-diagnostics and service tracking
  • Over-range sensor protection
  • Efficient "in the green" or "in the red" display box results allow for fine tuning combustion processes
  • Optional probes for high temperature, gas leak, ambient CO, and more
  • Large memory for up to 500,000 readings
  • Calculates CO2, efficiency, excess air, CO air free
 
For testing solid fuel during start up and shut down, use solid fuel adapter set 0600 9765.

 

Delivery Scope

testo 330-2 LX combustion analyzer, 12" flue gas probe with 7’ hose, extra particulate filters (10), AC power supply, rechargeable battery, certificate of conformity, and case
Differential Pressure

Measuring range

±40 InH₂O / ±10000 Pa

Accuracy

±0.0 InH₂O (0 to 0.04 InH₂O) plus ±1 Digit / ±0.3 Pa (0 to 9.99 Pa) plus ±1 Digit

±0 InH₂O (0 to 40 InH₂O) plus ±1 Digit / ±3 Pa (10 to 10000 Pa) plus ±1 Digit

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 20 sec

Flue gas CO

Measuring range

0 to 8000 ppm

Accuracy

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 8000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

CO determination (with H₂-compensation), automatic dilution

Measuring range

0 to 30000 ppm

Accuracy

±100 ppm (0 to 1000 ppm)

±10 % of mv (1001 to 30000 ppm)

Resolution

1 ppm

Flue Gas NO

Measuring range

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 %rH (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 30 sec

Flue gas NOlow

Measuring range

0 to 300 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 300 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 30 sec

Flue Gas Draft

Measuring range

-4.00 to +16 InH₂O / -9.99 to +40 hPa

Accuracy

±0.01 InH₂O or ±5 % of mv (-0.20 to +0.24 InH₂O) / ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.01 InH₂O (+0.24 to +1.20 InH₂O) / ±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+1.20 to +16.00 InH₂O) / ±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.00 InH₂O / 0.01 hPa

Temperature

Measuring range

-40° to 2192 °F / -40 to +1200 °C

Accuracy

±1 °F (32° to 212.0 °F) / ±0.5 °C (0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °F (-40° to 1831.8 °F) / 0.1 °C (-40 to +999.9 °C)

1.0 °F (> +1832 °F) / 1 °C (> +1000 °C)

Efficiency (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue Gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue Gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 sec

Velocity / Volume flow

Measuring range

29.50 to 591 fpm / 0.15 to 3 m/s

Resolution

0.1 fpm / 0.1 m/s

Pressure measurement

Measuring range

0 to +120 InH₂O / 0 to +300 hPa

Accuracy

±0.2 InH₂O (0.0 to 20.0 InH₂O) / ±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (20.0 to 40.0 InH₂O) / ±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

1{#0.0N} InH₂O / 0.1 hPa

Ambient CO

Measuring range

0 to 500 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (> 100 ppm)

Resolution

1 ppm

Reaction time

Approx. 35 sec

with CO probe

Ambient CO₂

Measuring range

0 to 1 Vol.%

0 to 10000 ppm

Accuracy

±50 ppm or ±2 % of mv (0 to 5000 ppm)

±100 ppm or ±3 % of mv (5001 to 10000 ppm)

Reaction time

Approx. 35 sec

with ambient CO₂ probe

Gas leak measurement for combustible gases (via gas leak detection probe)

Measuring range

0 to 10000 ppm CH₄ / C₃H₈; Display range

Accuracy

Signal optical display (LED) audible signal via buzzer

Reaction time t₉₀

< 2 sec

with gas leak detection probe

Temperature (via the fine pressure probe)

Measuring range

-40° to 2192 °F / -40 to +1200 °C max. (dependent on probe)

Accuracy

±1 °F (-40° to 212 °F) / ±0.5 °C (-40 to 100 °C)

±0.5 % of mv (Remaining Range) plus probe accuracy

Resolution

0.1 °F / 0.1 °C

General technical data

Dimensions

11 x 4 x 3 in. / 270 x 90 x 65 mm

Operating temperature

23° to 113 °F / -5 to +45 °C

Display size

240 x 320 pixels

Display function

Colour graphic display

Power supply

Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A

Maximum

500,000 readings

Storage temperature

-4° to 122 °F / -20 to +50 °C

Weight

21 oz. (without rechargeable battery) / 600 g (without rechargeable battery)

Probes

Connection cable

Order Number: 0430 0143

Mini ambient air probe

Order Number: 0600 3692

Temperature

Measuring range

32° to 176 °F / 0 to +80 °C

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Resolution

0.1 °F (32.0° to 212.0 °F) / 0.1 °C (0 to +100 °C)

Reaction time

30 sec

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Resolution

0.1 °F (33.8° to 212 {#0.0} °F) / 0.1 °C (1 to 100 {+#0} °C)

Reaction time

30 sec

Ambient CO₂

Measuring range

0 to +1 Vol.%

0 to +10000 ppm

Accuracy

±(75 ppm + 3 % of mv) (0 to +5000 ppm)

±(150 ppm + 5 % of mv) (+5001 to +10000 ppm)

Gas leak probe

Order Number: 0632 3330

Ambient CO probe

Order Number: 0632 3331

Ambient CO

Measuring range

0 to +500 ppm

Accuracy

±5 ppm (0 to +100 ppm)

±5 % of mv (+100.1 to +500 ppm)

Fine pressure probe

Order Number: 0638 0330

Temperature - Type K TC

Measuring range

Depends on probe, max. -40.0° to 2192.0 °F / Depends on probe, max. -40 to +1200 °C

-328.0° to 572.0 °F (with surface probe 0604 0994 (accessory)) / -200 to +300 °C (with surface probe 0604 0994 (accessory))

Accuracy

±0.9 °F (-40° to 212.0 °F) / ±0.5 °C (-40 to +100 °C)

±0.5 % of mv (Remaining Range) additionally ±1 digit, additionally accuracy of probe

Resolution

0.1 °F / 0.1 °C

Measuring rate

max. 1 / sec

Differential Pressure

Measuring range

-40.0 to +40.0 InH₂O / -9999.9 to +9999.9 Pa

Accuracy

±0.0 InH₂O (0 to +0.04 InH₂O) / ±0.3 Pa (0 to +9.99 Pa)

±3 % of mv (+0.04 to +40.0 InH₂O) additionally ±1 digit / ±3 % of mv (+10.00 to +9999.9 Pa) additionally ±1 digit

Resolution

0.01 InH₂O (-0.60° to 0.60 InH₂O) / 0.01 Pa (-149.99 to +149.99 Pa)

0.1 InH₂O (Remaining Range) / 0.1 Pa (Remaining Range)

Measuring rate

max. 1 / sec

Velocity / Volume flow

Measuring range

Display range: 29.50 to 591 fpm / Display range: 0.15 to 3 m/s

Resolution

0.1 fpm / 0.1 m/s

Instruments / options

Fine pressure probe

Order Number: 0638 0330

Measurement cells

Product Brochures

Manuals

Software

  • Update-Kit / Bootloader  (EXE, 380 KB) Download this file if you are using Microsoft Windows 8 or 10.  Firmware cannot be installed if this Update Kit file is not activated.
    This applies to Testo models 320, 330, 330i, 350)  See Installation Instructions PDF prior to installation.

  • Software EasyHeat for testo 312-4, 320, 324, 330, 380  (v2.11 ServicePack 1, EXE, 101.938 KB) If you already have the testo EasyHeat software installed, your version will be updated. The Update is possible with every version of the testo EasyHeat. This version can also be used as a demo version for  costumers  who don't have installed the testo easyheat software at the moment. It will void after 30-days, but can be activated with a serial code at every time.