testo 330-2 LX - Industrial combustion analyzer kit 2 with NOx measurement

Order-Nr.  400563 3372

  • NOx sensor included

  • Intuitive graphic display

  • Flue gas analyzer with onboard self-diagnostics

  • Long life sensors (up to six years) with over-range protection

The testo 330-2 LX combustion analyzer includes sensors to measure O2, CO, and NOx, for maximum combustion efficiency.  In addition, this flue gas analyzer performs boiler combustion analysis of temperature, pressure, and other required combustion efficiency parameters.

Product Description

For commercial and industrial boiler combustion analysis, the testo 330-2 LX combustion analyzer is properly outfitted with a NOx sensor, high range CO, sensor protection, a large memory for maintaining service records, and on-site printing capability.  The testo 330-2 LX combustion analyzer has the longest sensor warranty on the market – 4 years!  Rugged construction and high quality sensors provide years of combustion efficiency, reliability, and a very low cost of ownership.
 
  • Calculates NOx
  • Over-range sensor protection
  • Built-on dilution systems allow for CO readings of up to 30,000 ppm
  • Onboard self-diagnostics and service tracking
  • Efficient "in the green" or "in the red" display box results allow for fine tuning combustion processes
  • Optional probes for high temperature, gas leak, ambient CO, and more
  • Large memory for up to 500,000 readings
  • Calculates CO2, efficiency, excess air, CO air free
 
For testing solid fuel combustion during start up and shut down, use solid fuel adapter set 0600 9765.

 

Delivery Scope

testo 330-2 LX combustion analyzer with NOx measurement, 12" flue gas probe with 7’ hose, extra particulate filters (10), AC power supply, rechargeable battery, certificate of conformity, and case
Differential Pressure

Measuring range

0 to 120 InH₂O / 0 to 300 hPa

Accuracy

±0.2 InH₂O (0.0 to 20.0 InH₂O) / ±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (20.0 to 40.0 InH₂O) / ±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 InH₂O / 0.1 hPa

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 20 sec

Flue gas CO

Measuring range

0 to 8000 ppm

Accuracy

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 8000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 500 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 40 sec

CO determination (with H₂-compensation), automatic dilution

Measuring range

0 to 30000 ppm

Accuracy

±100 ppm (0 to 1000 ppm)

±10 % of mv (1001 to 30000 ppm)

Resolution

1 ppm

Flue Gas NO

Measuring range

0 to 3000 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (101 to 2000 ppm)

±10 % of mv (2001 to 3000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 30 sec

Flue gas NOlow

Measuring range

0 to 300 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (40 to 300 ppm)

Resolution

0.1 ppm

Reaction time t₉₀

< 30 sec

Flue Gas Draft

Measuring range

-4.00 to +16 InH₂O / -9.99 to +40 hPa

Accuracy

±0.01 InH₂O or ±5 % of mv (-0.20 to +0.24 InH₂O) / ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)

±0.01 InH₂O (+0.24 to +1.20 InH₂O) / ±0.03 hPa (+0.61 to +3.00 hPa)

±1.5 % of mv (+1.20 to +16.00 InH₂O) / ±1.5 % of mv (+3.01 to +40.00 hPa)

Resolution

0.01 InH₂O / 0.01 hPa

Temperature

Measuring range

-40° to 2192 °F * / -40 to +1200 °C *

Accuracy

±1 °F (32° to 212.0 °F) / ±0.5 °C (0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °F (-40° to 1831.8 °F) / 0.1 °C (-40 to +999.9 °C)

1.0 °F (> +1832 °F) / 1 °C (> +1000 °C)

* Measuring range depends on the connected flue gas probe

Efficiency (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue Gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue Gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 sec

Pressure measurement

Measuring range

0 to +120 InH₂O / 0 to +300 hPa

Accuracy

±0.2 InH₂O (0.0 to 20.0 InH₂O) / ±0.5 hPa (0.0 to 50.0 hPa)

±1 % of mv (20.0 to 40.0 InH₂O) / ±1 % of mv (50.1 to 100.0 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 InH₂O / 0.1 hPa

Flue gas CO (without H₂-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 60 sec

Ambient CO

Measuring range

0 to 500 ppm

Accuracy

±5 ppm (0 to 100 ppm)

±5 % of mv (> 100 ppm)

Resolution

1 ppm

Reaction time

Approx. 35 sec

with CO probe 0632 3331

Ambient CO₂

Measuring range

0 to 1 Vol.%

0 to 10000 ppm

Accuracy

±75 ppm or ±3 % of mv (0 to 5000 ppm)

±150 ppm or ±5 % of mv (5001 to 10000 ppm)

Reaction time

Approx. 35 sec

with ambient CO₂ probe 0632 1240

Gas leak measurement for combustible gases (via gas leak detection probe)

Measuring range

0 to 10000 ppm CH₄ / C₃H₈; Display range

Accuracy

Signal optical display (LED) audible signal via buzzer

Reaction time t₉₀

< 2 sec

with gas leak detection probe 0632 3330

General technical data

Dimensions

11 x 4 x 3 in. / 270 x 90 x 65 mm

Operating temperature

23° to 113 °F / -5 to +45 °C

Warranty

Instrument: 48 months; Probe: 48 months; Gas sensors (O₂, CO) 48 months; NO sensor 24 months; COlow sensor 24 months; Thermocouple 12 months; rechargeable battery: 12 months

Display size

240 x 320 pixels

Display function

Colour graphic display

Power supply

Rechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A

Maximum

500,000 readings

Storage temperature

-4° to 122 °F / -20 to +50 °C

Weight

21 oz. (without rechargeable battery) / 600 g (without rechargeable battery)

Probes

Connection cable

Order Number: 0430 0143

Mini ambient air probe

Order Number: 0600 3692

Temperature

Measuring range

32° to 176 °F / 0 to +80 °C

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Resolution

0.1 °F (32.0° to 212.0 °F) / 0.1 °C (0 to +100 °C)

Reaction time

30 sec

Temperature

Measuring range

32.0° to 212.0 °F / 0 to +100 °C

Resolution

0.1 °F (33.8° to 212 {#0.0} °F) / 0.1 °C (1 to 100 {+#0} °C)

Reaction time

30 sec

Ambient CO₂

Measuring range

0 to +1 Vol.%

0 to +10000 ppm

Accuracy

±(75 ppm + 3 % of mv) (0 to +5000 ppm)

±(150 ppm + 5 % of mv) (+5001 to +10000 ppm)

Gas leak probe

Order Number: 0632 3330

Ambient CO probe

Order Number: 0632 3331

Ambient CO

Measuring range

0 to +500 ppm

Accuracy

±5 ppm (0 to +100 ppm)

±5 % of mv (+100.1 to +500 ppm)

Fine pressure probe

Order Number: 0638 0330

Temperature - Type K TC

Measuring range

Depends on probe, max. -40.0° to 2192.0 °F / Depends on probe, max. -40 to +1200 °C

-328.0° to 572.0 °F (with surface probe 0604 0994 (accessory)) / -200 to +300 °C (with surface probe 0604 0994 (accessory))

Accuracy

±0.9 °F (-40° to 212.0 °F) / ±0.5 °C (-40 to +100 °C)

±0.5 % of mv (Remaining Range) additionally ±1 digit, additionally accuracy of probe

Resolution

0.1 °F / 0.1 °C

Measuring rate

max. 1 / sec

Differential Pressure

Measuring range

-40.0 to +40.0 InH₂O / -9999.9 to +9999.9 Pa

Accuracy

±0.0 InH₂O (0 to +0.04 InH₂O) / ±0.3 Pa (0 to +9.99 Pa)

±3 % of mv (+0.04 to +40.0 InH₂O) additionally ±1 digit / ±3 % of mv (+10.00 to +9999.9 Pa) additionally ±1 digit

Resolution

0.01 InH₂O (-0.60° to 0.60 InH₂O) / 0.01 Pa (-149.99 to +149.99 Pa)

0.1 InH₂O (Remaining Range) / 0.1 Pa (Remaining Range)

Measuring rate

max. 1 / sec

Velocity / Volume flow

Measuring range

Display range: 29.50 to 591 fpm / Display range: 0.15 to 3 m/s

Resolution

0.1 fpm / 0.1 m/s

Instruments / options

Fine pressure probe

Order Number: 0638 0330

Measurement cells

Product Brochures

Manuals

Software