testo 845 with integrated humidity module - Infrared temperature measuring instrument with integrated humidity module

Order-Nr.  0563 8451

  • Switchable optics for far-field (75:1) and close-focus (1 mm, distance 70 mm) measurements

  • Humidity module for determining surface moisture

  • Instrument memory for 90 measurement protocols

  • Visual and acoustic alarm if limit values exceeded

testo 845, infrared temperature measuring instrument with cross laser sightiing incl. humidity module, switchable optics for far-field and close focus measurement, contact temperature probe attachable, optical/audible alarm, reading logger, PC software incl. USB data transfer cable, aluminium case, battery and calibration protocol

Product Description

For the first time, surface temperatures with smallest diameters can be measured accurately at short and long distances. The switchable optics for far-field and close focus measurement make this possible.
Far-field measurements are carried out at an optical resolution of 75:1. In this way, surface temperatures can be measured accurately even at great distances from the object to be measured. At a distance of 1.2 metres from the object to be measured, the measuring spot diameter is only 16 mm. A cross laser marks the measuring spot exactly during measurement.
During measurements at a short distance from the object being measured, the close focus optics has a spot diameter of only 1 mm at a distance of 70 mm. Two laser points mark the spot exactly.

 

Delivery Scope

testo 845 infrared temperature measuring instrument with integrated humidity module, including case, calibration protocol, batteries, USB data cable and PC software.
Temperature - Type K TC

Measuring range

-31.0° to 1742.0 °F / -35 to +950 °C

Accuracy

±1.40 °F (-31.0° to 167.0 °F) / ±0.75 °C (-35 to +75 °C)

±1 % of mv (167.2° to 1742.0 °F) / ±1 % of mv (+75.1 to +950 °C)

Resolution

0.1 °F / 0.1 °C

Temperature - Infrared

Measuring range

-31.0° to 1742.0 °F / -35 to +950 °C

Accuracy

±4.5 °F (-31.0° to -4.2 °F) / ±2.5 °C (-35 to -20.1 °C)

±2.7 °F (-4.0° to 67.8 °F) / ±1.5 °C (-20 to +19.9 °C)

±1.40 °F (68.0° to 211.8 °F) / ±0.75 °C (+20 to +99.9 °C)

±0.75 % of mv (212.0° to 1742.0 °F) / ±0.75 % of mv (+100 to +950 °C)

Resolution

0.1 °F / 0.1 °C

Attachable humidity module - Capacitive

Measuring range

0.0 % to 100.0 %rH t2 n1{#0.0}° t1 n3{#0.0} {%S3} t2 n4{#0.0}° t1 n3{#0.0} {%S4}

32.0° to 122.0 °F / 0 to +50 °C

-20 to +50 °Ctd

Accuracy

±2 %rH (2 to 98 %rH)

±0.9 °F (50.0° to 104.0 °F) / ±0.5 °C (+10 to +40 °C)

±2 °F (Remaining Range) / ±1 °C (Remaining Range)

Resolution

0.1 °Ctd / 0.1 %rH

General technical data

Dimensions

6 x 2 x 8 in. / 155 x 58 x 195 mm

Operating temperature

-4.0° to 122.0 °F / -20 to +50 °C

Housing

black/gray, metal screen

Measuring rate

t95: 150 ms; Scanning Max/Min/Alarm: 100 ms

Optical resolution far field

75:1 16 mm @ 1200 mm (90%)

Optical resolution close focus

1 mm @ 70 mm (90%)

Battery type

2 AA batteries

Battery life

25 h (without laser), 10 h (with laser without light), 5 h (with laser and 50% light)

Storage temperature

-40.0° to 158.0 °F / -40 to +70 °C

Weight

16 oz. / 465 g

Air Probes

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

200 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Food Probe

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ²⁾

Reaction time

7 sec

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-58.0° to 446.0 °F / -50 to +230 °C

Accuracy

Class 1 ²⁾

Reaction time

15 sec

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Immersion / Penetration Probe

Temperature - Type K TC

Measuring range

-76.0° to 1832.0 °F / -60 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

2 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

7 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 1472.0 °F / -60 to +800 °C

Accuracy

Class 1 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-328.0° to 1832.0 °F / -200 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Surface probes

Temperature - Type K TC

Measuring range

-76.0° to 266.0 °F / -60 to +130 °C

Accuracy

Class 2 ²⁾

Reaction time

5 sec

2) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 572.0 °F / -60 to +300 °C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 1832.0 °F / -60 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

20 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Temperature - Type K TC

Measuring range

-76.0° to 572.0 °F / -60 to +300 °C

hort-term to 932.0°°F / hort-term to 500°C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

30 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 482.0 °F / -50 to +250 °C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 266.0 °F / -60 to +130 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 212.0 °F , short-term up to +130 °C / -50 to +100 °C , short-term up to +130 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 338.0 °F / -50 to +170 °C

Accuracy

Class 2 ¹⁾

Reaction time

150 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Magnetic probe (TC Type K)

Order Number: 0602 4892

Temperature - Type K TC

Measuring range

-58.0° to 752.0 °F / -50 to +400 °C

Accuracy

Class 2 ¹⁾

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 248.0 °F / -50 to +120 °C

Accuracy

Class 1 ¹⁾

Reaction time

90 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Thermocouples

Temperature - Type K TC

Measuring range

-58° to 752 °F / -50.0 to +400.0 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Product Brochures