testo 570s Smart Vacuum Kit with clamp meter - Smart digital manifold with wireless vacuum and clamp temperature probes plus clamp meter
0564 5704
testo 570s Smart Vacuum Kit with clamp meter - Smart digital manifold with wireless vacuum and clamp temperature probes plus clamp meter
Product no longer available. Have you checked out its successor? Why not enjoy the benefits that it has to offer: >> To the product
Long-term measurement with intelligent error analysis in the testo Smart App
World's longest battery life of up to 360 hours with rechargeable battery (USB-C) and batteries
Suitable for use with A3 and A2L refrigerants
In the kit: testo 570s digital manifold, 2x testo 115i wireless clamp temperature probes, 1x testo 552i wireless vacuum probe, 1x testo 770-3 TRMS clamp meter and case
requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0
Auto-off instrument
10 min
Battery life
With built-in rechargeable battery:; ≥220 h without Bluetooth®, without illumination; ≥120 h with Bluetooth® and illumination; With 3 AA batteries:; ≥145 h without Bluetooth®, without illumination; ≥75 h with Bluetooth® and illumination
Battery type
Built-in rechargeable battery: LI batttery 18650; Replaceable battery: 3 alkaline batteries AA
Radio range
150 m
Storage temperature
-20 to +60 °C
Temperature - NTC
Temperature - NTC
Measuring range
-40 to +150 °C
Accuracy
±1.3 °C (-20 to +85 °C)
Resolution
0.1 °C
General technical data
General technical data
Weight
127.4 g
Dimensions
183 x 90 x 30 mm
Operating temperature
-20 to +50 °C
Product-/housing material
Plastic
System requirements
requires iOS 13.0 or newer; requires Android 8.0 or newer; requires mobile end device with Bluetooth 4.0
Product colour
black/orange
Battery life
150 h
Battery type
3 AAA micro batteries
Data transfer
Bluetooth®
Radio range
100 m
Refrigerant
A2L / A3 compatibel
Storage temperature
-20 to +60 °C
Absolute Pressure
Absolute Pressure
Measuring range
0 to 26.66 mbar /
0 to 20000 micron
Accuracy
±(1
±10 micron + 10 % of mv (100 to 1000 micron)
Resolution
100 micron (2000 to 5000 micron) /
1 micron (0 to 1000 micron) /
10 micron (1000 to 2000 micron) /
Overload
absolute: 6.0 bar / 87 psi
(relative: 5.0 bar / 72 psi)
General technical data
General technical data
Weight
142 g
Dimensions
150 x 32 x 31 mm (LxWxH)
Operating temperature
-10 to +50 °C
Protection class
IP54
System requirements
requires iOS 13.0 or newer; requires Android 8.0 or newer; requires mobile end device with Bluetooth 4.2
Product colour
black/orange
Auto-off
10 min*
Battery type
3 AAA micro batteries
Battery life
39 h
Connection
7/16“ UNF
Interface
Bluetooth® 4.2
Storage temperature
-20 to +50 °C
* when not connected via Bluetooth
Temperature - TC Type K (NiCr-Ni)
Temperature - TC Type K (NiCr-Ni)
Measuring range
-20 to +500 °C
Accuracy
±1 °C (0 to +100 °C)
Resolution
0.2 °C
DC voltage
DC voltage
Measuring range
1.0 to 1000.0 V
Resolution
max. 1 mV
Accuracy
± (0.8 % of mv + 3 Digit)
AC voltage
AC voltage
Measuring range
1.0 mV to 1000.0 V
Resolution
max. 1 mV
Accuracy
± (1 % of mv + 3 Digit)
DC current
DC current
Measuring range
0.01 to 600.0 A (clamp)
0.1 to 600.0 μA (measuring cables)
Resolution
0.1 (clamp)
0.1 (measuring cables)
Accuracy
± (2 % of mv + 5 Digit) (measuring cables)
± (2 % of mv + 5 Digit) (clamp)
AC current
AC current
Measuring range
0.01 to 600.0 A (clamp)
0.1 to 600.0 μA (measuring cables)
Resolution
0.01 A (clamp)
0.1 μA (measuring cables)
Accuracy
± (2 % of mv + 5 Digit) (clamp)
± (1.5 % of mv + 5 Digit) (measuring cables)
Resistance
Resistance
Resolution
max. 0.01 Ohm
Measuring range
0.10 to 60.0 MOhm
Accuracy
± (1.5 % of mv + 3 Digit)
Capacitance
Capacitance
Resolution
max. 0.01 nF
Measuring range
0.001 μF to 60000.00 μF
Accuracy
± (1.5 % of mv + 5 Digit)
Frequency
Frequency
Resolution
max. 0.1 Hz
Measuring range
0.00 Hz to -10 kHz
Accuracy
± (1 % of mv + 1 Digit)
Active Power
Active Power
Measuring range
0.1 W to 600 kW
Accuracy
± (5 % of mv + 5 Digit)
Resolution
0.1 W
Reactive Power
Reactive Power
Measuring range
0.1 to 600.0 kvar
Accuracy
± (10 % of mv + 5 Digit)
Resolution
0.1 var
Apparent Power
Apparent Power
Measuring range
0.1 VA to 600.0 kVA
Accuracy
± 1 Digit
Resolution
0.1 VA
Direct current DC Voltage
Direct current DC Voltage
Measuring range
0.1 W to 600.0 kW
Accuracy
± 1 Digit
Resolution
max. 0.1 W
Power Factor
Power Factor
Measuring range
-1.00 to +1.00
Accuracy
± (10 % of mv + 5 Digit)
Resolution
0.01
General technical data
General technical data
Operating humidity
0 to 80.0 %RH
Weight
378 g
Dimensions
249 x 96 x 43 mm
Operating temperature
-10 to +50 °C
Connectable probes
1 x temperature probe (adapter required for type K thermocouples)
Product colour
Black
System requirements
requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0
Standards
EN 61326-1; EN 61010-2-032; EN 61140
Battery type
3 AAA micro batteries
Display size
2 lines
Display type
LCD (Liquid Crystal Display)
Interface
2 measuring jacks
Storage temperature
-15 to +60 °C
Overvoltage Category
CAT IV 600V; CAT III 1000V
Authorizations
CSA; CE
Internal_resistance
11 MOhm (AC / DC)
Instrument Measurement Functions
Instrument Measurement Functions
Diode test
yes
Continuity testing
yes
Display ligthing
yes
Hold
yes
MinMax
yes
Power Measurement
yes
Temperature measurement with adapter
yes
True RMS
yes
Inrush current measurement
yes
Bluetooth
yes
Display (counts)
6,000
Autom. measurement parameter detection
yes
μA current measuring range
yes
General technical data
General technical data
Weight
1200 g
Dimensions
455 x 320 x 108 mm
Product colour
Black
testo 570s digital 4-way manifold with lithium-ion rechargeable battery