Temperature - NTC | Measuring range -40 to +150 °C |
|---|---|
Accuracy ±0.5 % of mv ±1 Digit (Remaining Range) ±0.4 °C ±1 Digit (+75 to +99.9 °C) ±0.2 °C ±1 Digit (-25 to +74.9 °C) ±0.4 °C ±1 Digit (-40 to -25.1 °C) | |
Resolution 0.1 °C | |
Temperature - TC Type K (NiCr-Ni) | Measuring range -200 to +1370 °C |
|---|---|
Accuracy ±(0.3 °C + 0.1 % of mv) ±1 Digit | |
Resolution 0.1 °C | |
Differential pressure (internal sensor) - Piezoresistive | Measuring range 0 to +200 hPa |
|---|---|
Accuracy ±(0.1 hPa + 1.5 % of mv) ±1 Digit (25.001 to 200 hPa) ±(0.3 Pa + 1 % of mv) ±1 Digit (0 to 25 hPa) | |
Resolution 0.001 hPa | |
Absolute Pressure (internal sensor and external probe) | Measuring range 700 to 1100 hPa |
|---|---|
Accuracy ±3 hPa | |
Resolution 0.1 hPa | |
General technical data | Weight 510 g (instrument) |
|---|---|
Dimensions 210 x 95 x 39 mm ((LxWxH)) | |
Operating temperature -5 to +45 °C | |
Product-/housing material Plastic | |
Protection class IP40 | |
Connectable probes 4 x digital Bluetooth® probe or testo Smart Probe; 2 x digital probe with fixed cable or temperature probe NTC with fixed cable (via Testo Universal Connector - TUC); 2 x temperature probe TC type K with fixed cable | |
Product colour black/orange | |
Camera image size Main camera: 8.0 MP; Front camera: 5.0 MP | |
Battery life approx. 10 hrs continuous operation | |
Display type 5.0" touch display, HD 1280*720 pixels, IPS (160 k) | |
Power supply Rechargeable li-ion battery (5550 mAh) | |
Interface Bluetooth®; USB | |
Memory 2 GB; 1,000,000 measuring values | |
Storage temperature -20 to +60 °C | |
Temperature - TC Type K (NiCr-Ni) | Measuring range 0 to +120 °C |
|---|---|
Accuracy Class 1 ¹⁾ | |
| 1) According to standard EN 60584-1, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K). | |
General technical data | Weight 385 g |
|---|---|
Dimensions 250 x 150 x 150 mm | |
Cable length 1.4 m | |
Emissivity 0,95 | |
Probe head diameter 150 mm | |
Product colour Black | |
Temperature - NTC | Measuring range -40 to +150 °C |
|---|---|
Accuracy ±0.5 % of mv ±1 Digit (Remaining Range) ±0.4 °C ±1 Digit (+75 to +99.9 °C) ±0.2 °C ±1 Digit (-25 to +74.9 °C) ±0.4 °C ±1 Digit (-40 to -25.1 °C) | |
Resolution 0.1 °C | |
Temperature - TC Type K (NiCr-Ni) | Measuring range -200 to +1370 °C |
|---|---|
Accuracy ±(0.3 °C + 0.1 % of mv) ±1 Digit | |
Resolution 0.1 °C | |
General technical data | Storage temperature -20 to +60 °C |
|---|---|
Weight 162 g | |
Dimensions 136 x 89 x 39 mm (LxWxH) | |
Operating temperature -5 to +45 °C | |
Product-/housing material Plastic | |
Protection class IP20 | |
Product colour Black | |
Connectable probes 4 x digital probe with fixed cable or NTC temperature probe with fixed cable (via Testo Universal Connector - TUC); 2 x temperature probe TC type K with fixed cable | |
Cable length 1 m | |
Power supply External power supply via mains unit | |
Interface USB | |
Memory 360,000 measuring values; 1.5 MB | |
| *TUC connection (Testo Universal Connector): For the connection of fixed cable digital probes and NTC probes. | |
General technical data | Weight 5100 g |
|---|---|
Dimensions 730 x 220 x 245 mm ((LxWxH)) | |
Product colour Black | |
General technical data | Weight 3250 g |
|---|---|
Dimensions 520 x 410 x 210 mm LxWxH | |
Product-/housing material Plastic | |
Product colour Black | |