1. Home
  2. testo 176P1
0572 1767

testo 176P1 - Five-channel pressure, temperature, and RH data logger

Image
testo 176 P1 datalogger
The testo 176P1 pressure, temperature, and humidity measurement logger has a large display that makes it easy to read. The 176P1 is an ideal pressure, temperature, and RH data logger for the highly accurate and secure documentation of conditions in a laboratory, enviro chamber, clean room, or hospital control area. Creation of Excel Spreadsheets, PDFs, and data analysis are all easily achieved with the free, downloadable ComSoft software.
  • Professional software with Excel export function for programming the logger and data analysis
  • Records up to 5 measurements at the same time
  • Temperature measuring range from -20 °C to +70 °C
  • Easy-to-change battery
  • Automatic measuring data backup when the battery runs out or is changed
  • Displays violations of limit values
The testo 176P1 pressure, temperature, and RH data logger is an ideal, highly accurate data logger for the monitoring of pressures, temperatures, and humidity.
  • Internal pressure and external NTC sensor connections
  • Data transfer possible using the USB port, or SD card (optional)
  • Easy to read large display that shows current reading
  • IP54 protection class
  • Capable of CFR 21 Part 11 Compliancy
  • Free data logger software available for download
  • Data is secured within the logger, and can be password protected using ComSoft

Temperature - NTC

Measuring range
-4° to 158 °F / -20 to +70 °C
Accuracy
±0.7 °F (Remaining Range) ±1 Digit / ±0.4 °C (Remaining Range) ±1 Digit
±0.4 °F (-4° to 158 °F) ±1 Digit / ±0.2 °C (-20 to +70 °C) ±1 Digit
Resolution
0.1 °F / 0.1 °C

Humidity - Capacitive

Measuring range
0 to 100 %rH*
Accuracy
dependent on probe selected
Resolution
0.1 %rH
* Not for condensing atmospheres.

Absolute Pressure

Measuring range
9 to 16 psi / 600 to 1100 mbar
Accuracy
±0.0 psi (32° to 122 °F) ±1 Digit / ±3 mbar (0 to +50 °C) ±1 Digit
Resolution
0.0 psi / 0.1 mbar
testo 176P1 pressure, temperature, and humidity highly accurate measurement logger, batteries, certificate of conformity

Monitoring and documentation of laboratory conditions

The ambient conditions for research projects must frequently be documented in laboratories to check external influencing factors. In addition to recording temperature and humidity, this also includes checking the absolute pressure. There are major requirements in terms of reliability, along with tamper-proofing and data security of the recording instrument, as incorrect documentation could invalidate the whole research result. There are only a few instruments which can log all three measurement parameters at the same time and also offer the required amount of data security.

  • not available