Pressure measurement | Measuring range -15 to 870 psi / -1 to 60 bar |
|---|---|
Accuracy ±0.5 % Fs | |
Resolution 0.14 psi / 0.01 bar | |
Probe connection 3 x 7/16" – UNF | |
Overload rel. (high pressure) 943 psi / 65 bar | |
General technical data | Weight 20.99 oz. / 595 g |
|---|---|
Dimensions 3.03 x 4.29 x 2.48 in. / 77 x 109 x 63 mm | |
Operating temperature 14° to 122 °F / -10 to +50 °C | |
Protection class IP54 | |
System requirements requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0 | |
Product colour Black | |
Auto-off 10 min* | |
Battery life 130 h | |
Battery type 3 x AAA | |
Data transfer Bluetooth® | |
Radio range 492.12 ft. / 150 m | |
Refrigerants in instrument R114; R12; R123; R1233zd; R1234yf; R1234ze; R124; R125; R13; R134a; R22; R23; R290; R32; R401A; R401B; R402A; R402B; R404A; R407A; R407C; R407F; R407H; R408A; R409A; R410A; R414B; R416A; R420A; R421A; R421B; R422B; R422C; R422D; R424A; R427A; R434A; R437A; R438A; R442A; R444B; R448A; R449A; R450A; R452A; R452B; R453a; R454A; R454B; R454C; R455A; R458A; R500; R502; R503; R507; R513A; R600a; R718 (H₂O); R744 (CO₂) | |
Refrigerants update via App R11; FX80; I12A; R1150; R1270; R13B1; R14; R142B; R152A; R161; R170; R227; R236fa; R245fa; R401C; R406A; R407B; R407D; R41; Ra11A; R412A; R413A; R417A; R417B; R417C; R422A; R426A; R508A; R508B; R600; RIS89; SP22 | |
Refrigerant A2L / A3 compatibel | |
Storage temperature -4° to 140 °F / -20 to +60 °C | |
| * when not connected via Bluetooth | |
Temperature - NTC | Measuring range -40° to 302 °F / -40 to +150 °C |
|---|---|
Accuracy ±2.3 °F (-4° to 185 °F) / ±1.3 °C (-20 to +85 °C) | |
Resolution 0.1 °F / 0.1 °C | |
General technical data | Weight 4.49 oz. / 127.4 g |
|---|---|
Dimensions 7 x 4 x 1 in. / 183 x 90 x 30 mm | |
Operating temperature -4° to 122 °F / -20 to +50 °C | |
Housing Plastic | |
System requirements requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0 | |
Product colour black/orange | |
Battery type 3 x AAA | |
Battery life 150 h | |
Storage temperature -4° to 140 °F / -20 to +60 °C | |
Absolute Pressure | Measuring range 0 to 0.39 psi / / 0 to 26.66 mbar / 0 to 20000 micron |
|---|---|
Accuracy ±10 micron + 10 % of mv (100 to 1000 micron) | |
Resolution 100 micron (2000 to 5000 micron) / 1 micron (0 to 1000 micron) / 10 micron (1000 to 2000 micron) / | |
Overload absolute: 87.0 psi / 87 psi / absolute: 6.0 bar / 87 psi (relative: 72.5 psi / 72 psi) / (relative: 5.0 bar / 72 psi) | |
General technical data | Weight 5 oz. / 142 g |
|---|---|
Dimensions 6 x 1 x 1 in. (LxWxH) / 150 x 32 x 31 mm (LxWxH) | |
Operating temperature 14.0° to 122.0 °F / -10 to +50 °C | |
Protection class IP54 | |
System requirements requires iOS 12.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.2 | |
Product colour black/orange | |
Auto-off 10 min* | |
Battery type 3 x AAA | |
Battery life 39 h | |
Connection 7/16“ UNF | |
Interface Bluetooth® 4.2 | |
Storage temperature -4.0° to 122.0 °F / -20 to +50 °C | |
| * when not connected via Bluetooth | |
Temperature - NTC | Measuring range -4° to 140 °F / -20 to +60 °C |
|---|---|
Accuracy ±1.4 °F (-4° to 32 °F) / ±0.8 °C (-20 to 0 °C) ±0.9 °F (32° to 140 °F) / ±0.5 °C (0 to +60 °C) | |
Resolution 0.1 °F / 0.1 °C | |
Humidity - Capacitive | Measuring range 0 to 100 %rH |
|---|---|
Accuracy ±5 %rH (< 10 %rH or > 90 %rH) ±3.0 %rH (10 to 35 %rH) (at +77°F) / ±3.0 %RH (10 to 35 %RH) (at +25°C) ±2.0 %rH (35 to 65 %rH) (at +77°F) / ±2.0 %RH (35 to 65 %RH) (at +25°C) ±3.0 %rH (65 to 90 %rH) (at +77°F) / ±3.0 %RH (65 to 90 %RH) (at +25°C) | |
Resolution 0.1 %rH | |
General technical data | Weight 3.05 oz. / 86.4 g |
|---|---|
Dimensions 10 x 1 x 1 in. / 243 x 30 x 24 mm | |
Operating temperature -4° to 122 °F / -20 to +50 °C | |
Housing Plastic | |
System requirements requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0 | |
Product colour black/orange | |
Battery type 3 x AAA | |
Battery life 150 h | |
Length probe shaft 3.937 in. / 100 mm | |
Storage temperature -4° to 140 °F / -20 to +60 °C | |
General technical data | System requirements requires iOS 13.0 or newer; requires Android 8.0 or newer; requires mobile end device with Bluetooth 4.0 |
|---|---|
Some manufacturers specify exactly what the absolute pressure must be for you to evacuate your air conditioning systems and how long this pressure must be maintained. Compliance with these specifications is simple and easy thanks to the flexible setting of the alarm threshold in the testo 552.
Some manufacturers specify the desired micron lower limit that must be achieved to evacuate their air conditioning systems and how long this pressure must be maintained. Compliance with these specifications is simple and easy thanks to the flexible setting of the alarm threshold in the testo 552.
The testo 552 Digital Vacuum Gauge is for the evacuation of heat pumps, air conditioning, and refrigeration systems. The innovative testo 552 utilizes a sensor that, unlike the competition, requires no cleaning and is not affected by contamination. Never worry about a dirty sensor causing false readings. Trust your testo 552 to always be accurate.