| Measuring range | -50 to +150 °C |
|---|---|
| Accuracy | ±0,5 °C |
| Resolution | 0,1 °C |
| Probe connection | 2 x Plug-in (NTC) |
| Measuring range | -1 to 60 bar |
|---|---|
| Accuracy | ±0,25 % fs |
| Resolution | 0,01 bar |
| Probe connection | 3 x 7/16" – UNF + 1 x 5/8'' – UNF |
| Overload rel. (low pressure) | 65 bar |
| Overload rel. (high pressure) | 65 bar |
| Weight | 1,3 kg |
|---|---|
| Dimensions | 229 x 112,5 x 71 mm |
| Operating temperature | -20 to +50 °C |
| Protection class | IP54 |
| System requirements | requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0 |
| Auto-off instrument | 10 min |
| Battery life | With built-in rechargeable battery:; ≥220 h without Bluetooth®, without illumination; ≥120 h with Bluetooth® and illumination; With 3 AA batteries:; ≥145 h without Bluetooth®, without illumination; ≥75 h with Bluetooth® and illumination |
| Battery type | Built-in rechargeable battery: LI batttery 18650; Replaceable battery: 3 alkaline batteries AA |
| Radio range | 150 m |
| Storage temperature | -20 to +60 °C |
| Measuring range | -40 to +150 °C |
|---|---|
| Accuracy | ±1,3 °C (-20 to +85 °C) |
| Resolution | 0,1 °C |
| Weight | 127,4 g |
|---|---|
| Dimensions | 183 x 90 x 30 mm |
| Operating temperature | -20 to +50 °C |
| Product-/housing material | Plastic |
| System requirements | requires iOS 13.0 or newer; requires Android 8.0 or newer; requires mobile end device with Bluetooth 4.0 |
| Product colour | black/orange |
| Battery life | 150 h |
| Battery type | 3 AAA micro batteries |
| Data transfer | Bluetooth® |
| Radio range | 100 m |
| Refrigerant | A2L / A3 compatibel |
| Storage temperature | -20 to +60 °C |
| Measuring range | 0 to 26,66 mbar / 0 to 20000 micron |
|---|---|
| Accuracy | ±(1 ±10 micron + 10 % of mv (100 to 1000 micron) |
| Resolution | 100 micron (2000 to 5000 micron) / 1 micron (0 to 1000 micron) / 10 micron (1000 to 2000 micron) / |
| Overload | absolute: 6,0 bar / 87 psi (relative: 5,0 bar / 72 psi) |
| Weight | 142 g |
|---|---|
| Dimensions | 150 x 32 x 31 mm (LxWxH) |
| Operating temperature | -10 to +50 °C |
| Protection class | IP54 |
| System requirements | requires iOS 13.0 or newer; requires Android 8.0 or newer; requires mobile end device with Bluetooth 4.2 |
| Product colour | black/orange |
| Auto-off | 10 min* |
| Battery type | 3 AAA micro batteries |
| Battery life | 39 h |
| Connection | 7/16“ UNF |
| Interface | Bluetooth® 4.2 |
| Storage temperature | -20 to +50 °C |
| * when not connected via Bluetooth | |
| Measuring range | -20 to +500 °C |
|---|---|
| Accuracy | ±1 °C (0 to +100 °C) |
| Resolution | 0,2 °C |
| Measuring range | 1,0 to 1000,0 V |
|---|---|
| Resolution | max. 1 mV |
| Accuracy | ± (0,8 % of mv + 3 Digit) |
| Measuring range | 1,0 mV to 1000,0 V |
|---|---|
| Resolution | max. 1 mV |
| Accuracy | ± (1 % of mv + 3 Digit) |
| Measuring range | 0,1 to 600,0 μA (measuring cables) 0,01 to 600,0 A (clamp) |
|---|---|
| Resolution | 0,1 (clamp) 0,1 (measuring cables) |
| Accuracy | ± (2 % of mv + 5 Digit) (measuring cables) ± (2 % of mv + 5 Digit) (clamp) |
| Measuring range | 0,1 to 600,0 μA (measuring cables) 0,01 to 600,0 A (clamp) |
|---|---|
| Resolution | 0,01 A (clamp) 0,1 μA (measuring cables) |
| Accuracy | ± (1,5 % of mv + 5 Digit) (measuring cables) ± (2 % of mv + 5 Digit) (clamp) |
| Resolution | max. 0,01 Ohm |
|---|---|
| Measuring range | 0,10 to 60,0 MOhm |
| Accuracy | ± (1,5 % of mv + 3 Digit) |
| Resolution | max. 0,01 nF |
|---|---|
| Measuring range | 0,001 μF to 60000,00 μF |
| Accuracy | ± (1,5 % of mv + 5 Digit) |
| Resolution | max. 0,1 Hz |
|---|---|
| Measuring range | 0,00 Hz to -10 kHz |
| Accuracy | ± (1 % of mv + 1 Digit) |
| Measuring range | 0,1 W to 600 kW |
|---|---|
| Accuracy | ± (5 % of mv + 5 Digit) |
| Resolution | 0,1 W |
| Measuring range | 0,1 to 600,0 kvar |
|---|---|
| Accuracy | ± (10 % of mv + 5 Digit) |
| Resolution | 0,1 var |
| Measuring range | 0,1 VA to 600,0 kVA |
|---|---|
| Accuracy | ± 1 Digit |
| Resolution | 0,1 VA |
| Measuring range | 0,1 W to 600,0 kW |
|---|---|
| Accuracy | ± 1 Digit |
| Resolution | max. 0,1 W |
| Measuring range | -1,00 to +1,00 |
|---|---|
| Accuracy | ± (10 % of mv + 5 Digit) |
| Resolution | 0,01 |
| Operating humidity | 0 to 80,0 %RH |
|---|---|
| Weight | 378 g |
| Dimensions | 249 x 96 x 43 mm |
| Operating temperature | -10 to +50 °C |
| Connectable probes | 1 x temperature probe (adapter required for type K thermocouples) |
| Product colour | Black |
| System requirements | requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0 |
| Standards | EN 61326-1; EN 61010-2-032; EN 61140 |
| Battery type | 3 AAA micro batteries |
| Display size | 2 lines |
| Display type | LCD (Liquid Crystal Display) |
| Interface | 2 measuring jacks |
| Storage temperature | -15 to +60 °C |
| Overvoltage Category | CAT IV 600V; CAT III 1000V |
| Authorizations | CSA; CE |
| Internal_resistance | 11 MOhm (AC / DC) |
| Diode test | yes |
|---|---|
| Continuity testing | yes |
| Display ligthing | yes |
| Hold | yes |
| MinMax | yes |
| Power Measurement | yes |
| Temperature measurement with adapter | yes |
| True RMS | yes |
| Inrush current measurement | yes |
| Bluetooth | yes |
| Display (counts) | 6Â 000 |
| Autom. measurement parameter detection | yes |
| μA current measuring range | yes |
| Weight | 1200 g |
|---|---|
| Dimensions | 455 x 320 x 108 mm |
| Product colour | Black |