testo 340 - Combustion Analyzer for Commercial and Industrial Applications

Order-Nr.  0632 3340

This meter uses a sensor to start up. Click here for probe selection.
  • Flue gas analysis with up to 4 gas sensors - freely configurable with sensor change on site by the user

  • testo 340 flue gas analyzer, calibration protocol, shoulder strap, O2 sensor and integrated flow and pressure difference measurements   

  • Can measure CO, COlow, NO, NOlow, NO2 or SO2

  • Industrial use design

  • Measuring range extension even with high gas concentrations

  • Measurement data management on PC or notebook

The testo 340 standard kit includes the 340 portable 4-gas analyzer with O2 and CO sensors, transport case, power supply/rechargers, pack of 10 particle filters, 12" probe, 5/16" diameter, 7' Teflon hose assembly TMAX = 932 °F.
 
Testo 340s are sold through our Authorized Emissions Distributors network.  Please contact Testo to find your local distributor.


Details

Product Description

The testo 340 is the ideal tool to confirm proper set-up and to identify emission problems before they get serious.  Oxygen is the base sensor in all Testo 340 Analyzers.  Simply add one, or up to three sensors for your specific job.
 
This combustion analyzer can be configured in many ways for commissioning commercial boilers, testing engines in midstream gas pipelines, tuning industrial burners in refineries, or cement or glass or any other combustion system that requires high confidence, so you can make the proper control adjustments.
 

Four (4) gas flexibility – O2 comes standard, then choose what’s needed for your combustion tuning

Select the industrial CO sensors (0-10,000 ppm with a 50,000 ppm upper dilution range) for tuning standard systems or swap out and use the CO low range sensor (0-500 ppm) for critical low range carbon monoxide limits.  Add the NO and NO2 sensors for a NOx reading for tuning boilers or engines.  You can even field swap the standard NO sensor for the NOlow sensor and have 0.1 ppm NOx resolution for tighter combustion control.  Add the SO2 sensor to monitor sulfur laden fuels or additives.   We have a variety of kits configured for specific combustion tuning applications.   The analyzer Kits are configured to deliver the best performance whether you are testing a boiler or burner, stationary or mobile engine tuning, or pre-compliance testing.
 

Analyzer Kits - 4 Configured for typical combustion needs

  • Two gas: (O2, CO) standard combustion kit
  • Three gas: (O2, CO, NO) combustion kit for Boilers & Burners
  • Three gas: (O2, CO, NO) Engine Testing Kit
  • Single gas upgrade with O2 - Add what you need.

Built to last

  • Long life-time CO and NOx sensors (up to 5 years) make cost of ownership the best in market.  Field exchangeable sensors allow greater flexibility.
  • The automatic dilution (range extender) factor-5x increases the CO range to 50,000 ppm.  The analyzer will calculate and display the corrected values.  User defined setpoints means you can extend the CO sensor life and maintain accurate measurements.
  • Rubberized shock resistant housing and clear over-plate protects analyzer and display screen. Magnets on back housing allows you to mount the analyzer for easier viewing.

Beneficial features and useful options

  • The back-lit display is easily customized, can display from 4 to 8 lines, or show a variety of measurement options, such as PPM values or as MMBtu/hr. shows measurements
  • Important calculation including, combustion efficiency, excess air calculations, corrected NOx and corrected CO values.  
  • 18 fuels to choose from
  • Onboard Diagnostics – Simple Push the I button and scroll down to see instrument status.
  • Draft and differential pressure and Mass Emission calculations (i.e. lbs./hr., tons/yr) with any Pitot tube
  • Options:
     
    • Hose extensions -9-foot quick connect extensions with integrated thermocouple means you can extend the hose to 25 feet.  Simply disconnect them for easier, less bulky transport.
    • Industrial sample probes from 3 feet to 9 feet long and from 1,112 °F to 3,200 °F
    • Infrared printer
    • easyEmission Software - for real time data loggong or downloading from instrument memory
 

Delivery Scope

testo 340 flue gas analyzer, calibration certificate, shoulder strap, O2 sensor, and integrated flow and pressure difference measurements.
PLEASE NOTE: Your testo 340 must be fitted with a second gas sensor for it to work. Up to three additional sensors can be fitted.

Technical Data

Differential Pressure

Measuring range

-80 to 80 InH₂O / -200 to 200 hPa

Accuracy

±0.2 InH₂O (-20.0 to 20.0 InH₂O) / ±0.5 hPa (-49.9 to 49.9 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.0 InH₂O / 0.1 hPa

Absolute Pressure

Measuring range

+240 to +460 InH₂O / +600 to +1150 hPa

Accuracy

±4 InH₂O / ±10 hPa

Resolution

1 InH₂O / 1 hPa

Flue gas O₂

Measuring range

0 to 25 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.01 Vol.%

Reaction time t₉₀

< 20 sec

Flue gas CO

Measuring range

0 to 10000 ppm

Accuracy

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 10000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 40 sec

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K.

Resolution

0.1 ppm

Reaction time t₉₀

< 40 sec

Flue Gas NO

Measuring range

0 to 4000 ppm

Accuracy

±5 ppm (0 to 99 ppm)

±5 % of mv (100 to 1999 ppm)

±10 % of mv (2000 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 30 sec

Flue gas NOlow

Measuring range

0 to 300 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (Remaining Range)

Resolution

0.1 ppm

Reaction time t₉₀

< 30 sec

Flue Gas NO₂

Measuring range

0 to 500 ppm

Accuracy

±10 ppm (0 to 199 ppm)

±5 % of mv (Remaining Range)

Resolution

0.1 ppm

Reaction time t₉₀

< 40 sec

To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.

Flue Gas SO₂

Measuring range

0 to 5000 ppm

Accuracy

±10 ppm (0 to 99 ppm)

±10 % of mv (Remaining Range)

Resolution

1 ppm

Reaction time t₉₀

< 40 sec

To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.

Flue Gas Draft

Measuring range

-16 to +16 InH₂O / -40 to +40 hPa

Accuracy

±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-2.99 to +2.99 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.01 InH₂O / 0.01 hPa

Temperature

Measuring range

-40.0° to 2192.0 °F / -40 to +1200 °C

Accuracy

±0.9 °F (32.0° to 210.2 °F) / ±0.5 °C (0 to +99 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °F / 0.1 °C

Efficiency (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue Gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue Gas dewpoint (calculated)

Measuring range

0.0° to 99.9 °Ctd

Resolution

0.1 °Ctd

Flue Gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 sec

General technical data

Weight

34 oz. / 960 g

Dimensions

11 x 4 x 3 in. / 283 x 103 x 65 mm

Operating temperature

23° to 122 °F / -5 to +50 °C

Housing

TPE PC

Protection class

IP40

Connectable probes

1 x flue gas probe; 1 x temperature probe; 1 x differential pressure

Product colour

Black

Battery life

> 6h (Pumpe an, Displaybeleuchtung aus, bei 20°C)

Display function

Graphic display

Display size

160 x 240 pixels

Display type

graphic Display

Power supply

Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A

Hose length

max. 7.8 m (corresponds to two probe hose extensions)

Max. neg. press./flue gas

-2.901 psi / -200 mbar

Max. pos. press./flue gas

0.725 psi / 50 mbar

Pump flow

0.6 l/min (regulated)

User defined fuels

10 user-defined fuels incl. test gas as fuel

Maximum

100 folders

Storage per folder

Max. 10 sites

Storage per site

Max. 200 logs

Miscellaneous

The max. number of logs is determined by the number of folders or sites

Interface

Bluetooth®; USB; IR/IRDA interface; gas outlet; Mains connection; probe input/ probe inputs; Differential Pressure

Storage temperature

-4° to 122 °F / -20 to +50 °C


Probes

Temperature probes

Mini ambient air probe

Order Number: 0600 3692

$ 94.00
excl. tax
$ 165.00
excl. tax



Downloads

Manuals

Software

This meter uses a sensor to start up. Click here for probe selection.