testo 110 - One-channel temperature measuring instrument

Order-Nr.  0560 1108

  • Extremely accurate in very low temperature ranges, i.e. cold storage rooms

  • Optional connectable temperature sensor and wireless sensor for different applications in the field

  • Audible alarm, user-defined thresholds

  • HACCP compliant, certified according to EN 13485 for use in the food sector

Cold storage rooms, cold storage warehouses, outdoors: the testo 110 digital temperature meter shows what it’s really made of when temperatures start to drop. Thanks to NTC technology, it can measure temperatures in very low temperature environments.

This meter uses a sensor to start up.

Click here for probe selection.

Product Description

Minus 20 degrees Celsius is what most of us would call really cold. But for others, it’s just a normal part of their working lives. The testo 110 temperature meter provides such people with an extremely accurate means of carrying out temperature measurements at extremely low temperatures. Ideal for use outdoors and in cold storage houses.

At-a-glance look at the benefits of the testo 110

  • Precision you can rely on, including at very low temperatures – thanks to NTC technology: cold storage rooms, cold storage warehouses, outdoors – just a few of the places where you can count on the testo 110 to provide you with precise and reliable results
  • Special features: large, two-line display; user-defined thresholds; audible alarm alerts when thresholds are exceeded; min/max value recognition; auto-hold
  • Wide range of optional NTC sensors to suit your individual requirements: includes a wide variety of food sensors, i.e. frozen food probe, penetration/immersion probe, surface sensors
  • Further practical accessories: from the TopSafe dishwasher safe protective cover to the testo turbo printer for on-the-spot print outs

 

Delivery Scope

testo 110 digital temperature meter, calibration certificate, and batteries
Please note: You will need a temperature sensor to use your meter. The accuracy of your measurements depends on the accuracy of the sensor and the accuracy of your meter.
Temperature - NTC

Measuring range

-58.0° to 302.0 °F / -50 to +150 °C

Accuracy

±0.4° °F (-4° to +176 °F) / ±0.2 °C (-20 to +80 °C)

±0.5 °F Remaining Range / ±0.3 °C Remaining Range

Resolution

0.1 °F / 0.1 °C

General technical data

Dimensions

7 x 2 x 2 in. / 182 x 64 x 40 mm

Operating temperature

-4.0° to 122.0 °F / -20 to +50 °C

Housing

ABS

Number of channels

1-channel

Standards

EN 13485

Battery type

9V block battery

Battery life

200 h (connected probe, backlight off); 45 h (radio mode, backlight off); 68 h (connected probe, backlight always on); 33 h (radio mode, backlight always on)

Storage temperature

-40.0° to 158.0 °F / -40 to +70 °C

Weight

6 oz. / 171 g

Air Probes

Temperature - NTC

Measuring range

-58.0° to 257.0 °F / -50 to +125 °C ²⁾

Accuracy

±0.4 °F (-13 to +176 °F) / ±0.2 °C (-25 to +80 °C)

±0.7 °F (Remaining Range) / ±0.4 °C (Remaining Range)

Reaction time

60 sec

1) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)

Air and Immersion / Penetration RFID Probe

Temperature - Type K TC

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Short-term to: +932 °F / Short-term to: +500 °C

Accuracy

±(0.9 °F + 0.3 % of mv) (-40.0° to 932 °F / ±(0.5 °C + 0.3 % of mv) (-40 to +500 °C

±(1.3 °F + 0.5 % of mv) (n3{#0.0} Remaining Range n4{#0.0} {%S3} / ±(0.7 °C + 0.5 % of mv) (Remaining Range)

Resolution

0.1 °F (-58.0 to 391.8 °F) / 0.1 °C (-50 to +199.9 °C)

1.0 °F Remaining Range / 1.0 °C Remaining Range

Reaction time

(in water) 10 sec

Food Probe

Temperature - NTC

Measuring range

-58.0° to 302.0 °F / -50 to +150 °C ¹⁾

Accuracy

±0.5 % of mv (212.0° to 302.0 °F) / ±0.5 % of mv (+100 to +150 °C)

±0.4 °F (-13.0° to 166.8 °F) / ±0.2 °C (-25 to +74.9 °C)

32.7 °F / ±0.4 °C (Remaining Range)

Reaction time

8 sec

1) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)

Temperature - NTC

Measuring range

-13.0° to 302.0 °F ¹⁾ / -25 to +150 °C ¹⁾

Accuracy

±0.5 % of mv (212.0° to 302.0 °F) / ±0.5 % of mv (+100 to +150 °C)

±0.4 °F (-13.0° to 166.8 °F) / ±0.2 °C (-25 to +74.9 °C)

±0.7 °F (remaining range) / ±0.4 °C (remaining range)

Reaction time

7 sec

1) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)

Temperature - NTC

Measuring range

-58.0° to 284.0 °F / -50 to +140 °C ¹⁾

Accuracy

±0.5 % of mv (+212 to +284 °F) / ±0.5 % of mv (+100 to +140 °C)

±0.4 °F (-13.0° to 166.8 °F) / ±0.2 °C (-25 to +75 °C)

32.7 °F / ±0.4 °C (Remaining Range)

Reaction time

20 sec

1) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)

Temperature - NTC

Measuring range

-58.0° to 302.0 °F / -50 to +150 °C ¹⁾

Accuracy

±0.5 % of mv (212.0° to 302.0 °F) / ±0.5 % of mv (+100 to +150 °C)

±0.4 °F (-13.0° to 166.8 °F) / ±0.2 °C (-25 to +74.9 °C)

32.7 °F / 0.4 °C

Reaction time

8 sec

1) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)

Immersion / Penetration Probe

Temperature - NTC

Measuring range

-58.0° to 302.0 °F / -50 to +150 °C

Accuracy

±0.5 % of mv (212.0° to 302.0 °F) / ±0.5 % of mv (100 to +150 °C)

±0.4 °F (-13.0° to 166.8 °F) / ±0.2 °C (-25 to +74.9 °C)

±0.7 °F (remaimig range) / ±0.4 °C (remaimig range)

Reaction time

10 sec

Immersion / Penetration RFID Probe

Surface RFID Probe

Temperature - Type K TC

Measuring range

-58.0 to 662.0 °F / -50 to +350 °C

Short-term to: +932 °F / Short-term to: +500 °C

Accuracy

Radio handle:

±(0.9 °F + 0.3 % of mv) (-40.0 to 932.0 °F) / ±(0.5 °C + 0.3 % of mv) (-40 to +500 °C)

±(1.3 °F + 0.5 % of mv) (Remaining Range) / ±(0.7 °C + 0.5 % of mv) (Remaining Range)

T/C probe head: Class 2

Resolution

0.1 °F (-58.0 to 391.8 °F) / 0.1 °C (-50 to +199.9 °C)

1.0 °F Remaining Range / 1.0 °C Remaining Range

Reaction time

5 sec

Surface probes

Temperature - NTC

Measuring range

-58.0 to 302.0 °F ¹⁾ / -50 to +150 °C ¹⁾

Accuracy

±0.5 % of mv (212.0° to 302.0 °F) / ±0.5 % of mv (100 to +150 °C)

±0.4 °F (-13.0° to 166.8 °F) / ±0.2 °C (-25 to +74.9 °C)

±0.7 °F (Remaining Range) / ±0.4 °C (Remaining Range)

Reaction time

35 sec

1) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)

Temperature - NTC

Measuring range

-58.0° to 158.0 °F / -50 to +70 °C ¹⁾

Accuracy

±0.4 °F (-13.0° to 158.0 °F) / ±0.2 °C (-25 to +70 °C)

±0.7 °F (-58.0° to -13.2 °F) / ±0.4 °C (-50 to -25.1 °C)

Reaction time

60.0 sec

1) Long-term measurement range +125°C, short-term +150°C or +140°C (2 minutes)