testo 925 - Type K Thermometer

Order-Nr.  0560 9250

  • 1 channel measuring instrument with optional radio probe

  • Hold button to freeze reading

  • Continuous display of max/min values

  • An audible alarm sounds when limit values are exceeded

Testo 925 Type K thermocouple thermometer, audible alarm, with battery and calibration document

This meter uses a sensor to start up.

Click here for probe selection.

Product Description

The testo 925 Type K thermocouple thermometer uses both corded and optional wireless probes, displaying both temperatuers simultaneously. A user-adjustable and audible alarm sounds if set limits are exceeded, making this a reliable QC instrument. Measurements as well as Max-Min values with time/date can be printed on-site with the optional testo printer.

 

Delivery Scope

testo 925 temperature measuring instrument, including batteries and calibration protocol.
Note: the temperature measuring instrument requires a probe for commissioning (not included in the scope of delivery).
Temperature - Type K TC

Measuring range

-58.0° to 1832.0 °F / -50 to +1000 °C

Accuracy

±(0.9 °F + 0.3 % of mv) (-40.0° to 1652.0 °F) / ±(0.5 °C + 0.3 % of mv) (-40 to +900 °C)

±(1.3 °F + 0.5 % of mv) (Remaining Range) / ±(0.7 °C + 0.5 % of mv) (Remaining Range)

Resolution

0.1 °F (-58.0 to +391.8 °F) / 0.1 °C (-50 to +199.9 °C)

1.0 °F (Remaining Range) / 1 °C (Remaining Range)

General technical data

Dimensions

7 x 3 x 2 in. / 182 x 65 x 40 mm

Operating temperature

-4.0° to 122.0 °F / -20 to +50 °C

Housing

ABS

Number of channels

1-channel

Battery type

9V block battery, 6F22

Battery life

200 h (connected probe, backlight off); 45 h (radio mode, backlight off); 68 h (connected probe, backlight always on); 33 h (radio mode, backlight always on)

Storage temperature

-40.0° to 158.0 °F / -40 to +70 °C

Weight

6 oz. / 171 g

Air Probes

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

200 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Air and Immersion / Penetration RFID Probe

Temperature - Type K TC

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Short-term to: +932 °F / Short-term to: +500 °C

Accuracy

±(0.9 °F + 0.3 % of mv) (-40.0° to 932 °F / ±(0.5 °C + 0.3 % of mv) (-40 to +500 °C

±(1.3 °F + 0.5 % of mv) (n3{#0.0} Remaining Range n4{#0.0} {%S3} / ±(0.7 °C + 0.5 % of mv) (Remaining Range)

Resolution

0.1 °F (-58.0 to 391.8 °F) / 0.1 °C (-50 to +199.9 °C)

1.0 °F Remaining Range / 1.0 °C Remaining Range

Reaction time

(in water) 10 sec

Food Probe

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ²⁾

Reaction time

7 sec

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-58.0° to 446.0 °F / -50 to +230 °C

Accuracy

Class 1 ²⁾

Reaction time

15 sec

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Immersion / Penetration Probe

Temperature - Type K TC

Measuring range

-76.0° to 1832.0 °F / -60 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

2 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

7 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 1472.0 °F / -60 to +800 °C

Accuracy

Class 1 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-328.0° to 2372.0 °F / -200 to +1300 °C

Accuracy

Class 1 ¹⁾

Reaction time

4 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-328.0° to 1832.0 °F / -200 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Immersion tip, flexible

Order Number: 0602 5793

Temperature - Type K TC

Measuring range

-328.0° to 104.0 °F / -200 to +40 °C

Class 3 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Immersion / Penetration RFID Probe

Surface RFID Probe

Temperature - Type K TC

Measuring range

-58.0 to 662.0 °F / -50 to +350 °C

Short-term to: +932 °F / Short-term to: +500 °C

Accuracy

Radio handle:

±(0.9 °F + 0.3 % of mv) (-40.0 to 932.0 °F) / ±(0.5 °C + 0.3 % of mv) (-40 to +500 °C)

±(1.3 °F + 0.5 % of mv) (Remaining Range) / ±(0.7 °C + 0.5 % of mv) (Remaining Range)

T/C probe head: Class 2

Resolution

0.1 °F (-58.0 to 391.8 °F) / 0.1 °C (-50 to +199.9 °C)

1.0 °F Remaining Range / 1.0 °C Remaining Range

Reaction time

5 sec

Surface probes

Temperature - Type K TC

Measuring range

-76.0° to 266.0 °F / -60 to +130 °C

Accuracy

Class 2 ²⁾

Reaction time

5 sec

2) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

32.0° to 572.0 °F / 0 to +300 °C

Accuracy

Class 2 *

Reaction time

5 sec

* According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 572.0 °F / -60 to +300 °C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 1832.0 °F / -60 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

20 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Temperature - Type K TC

Measuring range

-76.0° to 572.0 °F / -60 to +300 °C

hort-term to 932.0°°F / hort-term to 500°C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

30 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 482.0 °F / -50 to +250 °C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 266.0 °F / -60 to +130 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 212.0 °F , short-term up to +130 °C / -50 to +100 °C , short-term up to +130 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 338.0 °F / -50 to +170 °C

Accuracy

Class 2 ¹⁾

Reaction time

150 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Magnetic probe (TC Type K)

Order Number: 0602 4892

Temperature - Type K TC

Measuring range

-58.0° to 752.0 °F / -50 to +400 °C

Accuracy

Class 2 ¹⁾

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 248.0 °F / -50 to +120 °C

Accuracy

Class 1 ¹⁾

Reaction time

90 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Thermocouples

Temperature - Type K TC

Measuring range

-58° to 752 °F / -50.0 to +400.0 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.