testo 735-2 - Multichannel thermometer

Order-Nr.  0563 7352

  • Up to 3 connectable and 3 wireless temperature sensors

  • Super-size memory for up to 10,000 readings; PC software and USB cable included

  • High-precision optional sensor for accuracy of up to 0.09 °F

  • IP65 rated (dust/water ingress) HACCP / EN 13485 compliant

Calibrating static temperature sensors, temperature measurements in the cosmetics and food industries, laboratories, the cooling and refrigeration sector: the testo 735-2 multichannel thermometer can master virtually any application, thanks to wireless data transfer, a super-size memory, and a wide range of optional sensors.

This meter uses a sensor to start up.

Click here for probe selection.

Product Description

The testo 735-2 digital multichannel thermometer is used in a variety of different fields. It can measure the surface, air, and core temperature of a wide range of media, with an accuracy up to 0.09 °F (using high-precision Pt immersion / penetration sensors). Can be wirelessly connected to as many as 3 external temperature sensors, whose readings are then transmitted to the display, so what you get is not a 3, but a 6-channel meter!

Wide selection of sensors – precise measurements on up to 6 channels

The testo 735-2 multichannel thermometer has a sensor connecting point for a highly-accurate Pt100 sensor, and two connecting points for quick type K, T, J, and S thermoelement sensors. Six sensors, 3 of them wireless temperature sensors, can be connected to the meter. A wide selection of immersion / penetration / surface sensors is available to help you carry out quick and accurate temperature measurements on a variety of different surfaces and media.
The high precision Pt100 immersion / penetration sensor (optional) has a system accuracy of 0.09 °F, and a resolution of 0.0018 °F. This makes the testo 735-2 ideal for use as a working standard.

For measuring, saving, and analyzing temperature measurements with multiple profiles

The testo 735-2 allows you to carry out quick and precise temperature measurements, save up to 10,000 readings, and create as many as 99 measuring sites and multiple user profiles.
You can also save individual protocols or measurement series for each measuring site, and select a memory cycle from 0.5 seconds to 24 hours. The software (included) allows you to save and analyze measuring data as a table or graphic. Optional wireless turbo printer for on-the-spot print outs.

Highly precise – highly practical

The testo 735-2 provides you with delta T and min/max/avg values. The readings are presented on a backlit display (ideal in poorly lit conditions). An acoustic alarm is triggered when thresholds are breached. IP65 rated and EN 13485 certified / HACCP compliant / HACCP International certified.

 

Delivery Scope

testo 735-2 digital multichannel thermometer (3-channel), PC software, USB data cable, calibration protocol, and batteries

PLEASE NOTE: sensor required (not in scope of supply).

Temperature - Pt100

Measuring range

-328.0° to 1472.0 °F / -200 to +800 °C

Accuracy

±0.4 °F (-148.0° to 391.8 °F) / ±0.2 °C (-100 to +199.9 °C)

±0.2 % of mv (Remaining Range)

Resolution

0.1 °F / 0.05 °C

Temperature - Type K TC

Measuring range

-328.0° to 2498.0 °F / -200 to +1370 °C

Accuracy

±0.5 °F (-76.0° to 140.0 °F) / ±0.3 °C (-60 to +60 °C)

±(0.4 °F + 0.3 % of mv) (Remaining Range) / ±(0.2 °C + 0.3 % of mv) (Remaining Range)

Resolution

0.1 °F / 0.1 °C

Temperature - TC Type T (Cu-CuNi)

Measuring range

-328.0° to 752.0 °F / -200 to +400 °C

Accuracy

±0.5 °F (-76.0° to 140.0 °F) / ±0.3 °C (-60 to +60 °C)

±(0.4 °F + 0.3 % of mv) (Remaining Range) / ±(0.2 °C + 0.3 % of mv) (Remaining Range)

Resolution

0.1 °F / 0.1 °C

Temperature - Type J TC

Measuring range

-328.0° to 1832.0 °F / -200 to +1000 °C

Accuracy

±0.5 °F (-76.0° to 140.0 °F) / ±0.3 °C (-60 to +60 °C)

±(0.4 °F + 0.3 % of mv) (Remaining Range) / ±(0.2 °C + 0.3 % of mv) (Remaining Range)

Resolution

0.1 °F / 0.1 °C

Temperature - TC Type S (Pt10Rh-Pt)

Measuring range

32.0° to 3200.0 °F / 0 to +1760 °C

Accuracy

±1.8 °F (32.0° to 3200.0 °F) / ±1 °C (0 to +1760 °C)

Resolution

1.0 °F / 1 °C

General technical data

Dimensions

9 x 3 x 2 in. / 220 x 74 x 46 mm

Operating temperature

-4.0° to 122.0 °F / -20 to +50 °C

Housing

ABS / TPE / Metal

Protection class

IP65

Standards

EN 13485

Battery type

Alkaline, type AA

Storage temperature

-22.0° to 158.0 °F / -30 to +70 °C

Weight

15 oz. / 428 g

Air Probes

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

200 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Accuracy

±0.4 °F (-4 to +158 °F) / ±0.2 °C (-20 to +70 °C)

Class 1 (t1) ¹⁾

Reaction time

25 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +350 °C (Type T).

Temperature - Pt100

Measuring range

-58.0° to 752.0 °F / -50 to +400 °C

Accuracy

Class A (-58 to +572 °F) / Class A (-50 to +300 °C)

Class B (Remaining Range) ¹⁾  

Reaction time

70 sec

1) According to standard 60751, the accuracies of Class A and B refer to -200 to +600 °C (Pt100)

Air and Immersion / Penetration RFID Probe

Temperature - Type K TC

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Short-term to: +932 °F / Short-term to: +500 °C

Accuracy

±(0.9 °F + 0.3 % of mv) (-40.0° to 932 °F / ±(0.5 °C + 0.3 % of mv) (-40 to +500 °C

±(1.3 °F + 0.5 % of mv) (n3{#0.0} Remaining Range n4{#0.0} {%S3} / ±(0.7 °C + 0.5 % of mv) (Remaining Range)

Resolution

0.1 °F (-58.0 to 391.8 °F) / 0.1 °C (-50 to +199.9 °C)

1.0 °F Remaining Range / 1.0 °C Remaining Range

Reaction time

(in water) 10 sec

Food Probe

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ²⁾

Reaction time

7 sec

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Accuracy

±0.4 °F (-4.0° to 158.0 °F) / ±0.2 °C (-20 to +70 °C)

Class 1 (Remaining Range) ¹⁾

Reaction time

7 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +350 °C (Type T).

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Accuracy

±0.4 °F (-4.0° to 158.0 °F) / ±0.2 °C (-20 to +70 °C)

Class 1 (Remaining Range) ¹⁾

Reaction time

7 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +350 °C (Type T).

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Accuracy

±0.4 °F (-4.0° to 158.0 °F) / ±0.2 °C (-20 to +70 °C)

Class 1 (Remaining Range) ¹⁾

Reaction time

6 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +350 °C (Type T).

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Accuracy

±0.4 °F (-4.0° to 158.0 °F) / ±0.2 °C (-20 to +70 °C)

Class 1 (Remaining Range) ¹⁾

Reaction time

8 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +350 °C (Type T).

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Accuracy

±0.4 °F (-4.0° to 158.0 °F) / ±0.2 °C (-20 to +70 °C)

Class 1 (Remaining Range) ¹⁾

Reaction time

7 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +350 °C (Type T).

Temperature - Pt100

Measuring range

-58 to +752 °F / -50 to +400 °C

Accuracy

Class A (-58.0° to 572.0 °F) / Class A (-50 to +300 °C)

Class B (Remaining Range) ¹⁾

Reaction time

10 sec

1) According to standard 60751, the accuracies of Class A and B refer to -200 to +600 °C (Pt100)

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 662.0 °F / -50 to +350 °C

Accuracy

±1.8 °F (-40.0° to 271.4 °F) / ±1.0 °C (-40 to +133 °C)

Class 2 Remaining Range

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 1 and Class 2 refers to -40 to +350 °C (Type T).

Temperature - Type K TC

Measuring range

-76.0° to 482.0 °F / -60 to +250 °C

Accuracy

Class 1 ²⁾

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 482.0 °F / -50 to +250 °C

Accuracy

±0.4 °F (-4.0° to 158.0 °F) / ±0.2 °C (-20 to +70 °C)

Class 1 (Remaining Range) ¹⁾

Reaction time

2 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +350 °C (Type T).

Temperature - TC Type T (Cu-CuNi)

Measuring range

-58.0° to 482.0 °F / -50 to +250 °C

Accuracy

±0.4 °F (-4.0° to 158.0 °F) / ±0.2 °C (-20 to +70 °C)

Class 1 (Remaining Range) ¹⁾

Reaction time

2 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +350 °C (Type T).

Temperature - Type K TC

Measuring range

-58.0° to 446.0 °F / -50 to +230 °C

Accuracy

Class 1 ²⁾

Reaction time

15 sec

2) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Immersion / Penetration Probe

Temperature - Type K TC

Measuring range

-328.0° to 1832.0 °F / -200 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

1 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-76.0° to 1832.0 °F / -60 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

2 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

7 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 1472.0 °F / -60 to +800 °C

Accuracy

Class 1 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Temperature - Type K TC

Measuring range

-328.0° to 1832.0 °F / -200 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Temperature - Pt100

Measuring range

-58.0° to 752.0 °F / -50 to +400 °C

Accuracy

Class A (-58 to +572 °F) / Class A (-50 to +300 °C)

Class B (Remaining Range) ¹⁾

Reaction time

12 sec

1) According to standard 60751, the accuracies of Class A and B refer to -200 to +600 °C (Pt100)

Temperature - Pt100

Measuring range

-112.0° to 572.0 °F / -80 to +300 °C

Accuracy

±0.5 °F (-112 to -40 °F) / ±0.3 °C (-80 to -40 °C)

±(0.2 °F + 0.05 % of mv) (-40.0° to 32.0 °F) / ±(0.1 °C + 0.05 % of mv) (-40 to 0 °C)

±0.10 °F (32 to +212 °F) / ±0.05 °C (0 to +100 °C)

±(0.10 °F + 0.05 % of mv) (212.0° to 572.0 °F) / ±(0.05 °C + 0.05 % of mv) (100 to 300 °C)

Reaction time

60 sec

Immersion / Penetration RFID Probe

Laboratory probes

Temperature - Pt100

Measuring range

-58 to +752 °F / -50 to +400 °C

Accuracy

Class A (-58 to +572 °F) / Class A (-50 to +300 °C)

Class B (Remaining Range) ¹⁾

Reaction time

45 sec

1) According to standard 60751, the accuracies of Class A and B refer to -200 to +600 °C (Pt100)

Surface RFID Probe

Temperature - Type K TC

Measuring range

-58.0 to 662.0 °F / -50 to +350 °C

Short-term to: +932 °F / Short-term to: +500 °C

Accuracy

Radio handle:

±(0.9 °F + 0.3 % of mv) (-40.0 to 932.0 °F) / ±(0.5 °C + 0.3 % of mv) (-40 to +500 °C)

±(1.3 °F + 0.5 % of mv) (Remaining Range) / ±(0.7 °C + 0.5 % of mv) (Remaining Range)

T/C probe head: Class 2

Resolution

0.1 °F (-58.0 to 391.8 °F) / 0.1 °C (-50 to +199.9 °C)

1.0 °F Remaining Range / 1.0 °C Remaining Range

Reaction time

5 sec

Surface probes

Temperature - Type K TC

Measuring range

-76.0° to 266.0 °F / -60 to +130 °C

Accuracy

Class 2 ²⁾

Reaction time

5 sec

2) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

32.0° to 572.0 °F / 0 to +300 °C

Accuracy

Class 2 *

Reaction time

5 sec

* According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 572.0 °F / -60 to +300 °C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 1832.0 °F / -60 to +1000 °C

Accuracy

Class 1 ¹⁾

Reaction time

20 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Temperature - Type K TC

Measuring range

-76.0° to 572.0 °F / -60 to +300 °C

hort-term to 932.0°°F / hort-term to 500°C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 752.0 °F / -60 to +400 °C

Accuracy

Class 2 ¹⁾

Reaction time

30 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 482.0 °F / -50 to +250 °C

Accuracy

Class 2 ¹⁾

Reaction time

3 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-76.0° to 266.0 °F / -60 to +130 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 212.0 °F , short-term up to +130 °C / -50 to +100 °C , short-term up to +130 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Type K TC

Measuring range

-58.0° to 338.0 °F / -50 to +170 °C

Accuracy

Class 2 ¹⁾

Reaction time

150 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Magnetic probe (TC Type K)

Order Number: 0602 4892

Temperature - Type K TC

Measuring range

-58.0° to 752.0 °F / -50 to +400 °C

Accuracy

Class 2 ¹⁾

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Temperature - Pt100

Measuring range

-58.0° to 752.0 °F / -50 to +400 °C

Accuracy

Class B ¹⁾

Reaction time

40 sec

1) According to standard 60751, the accuracies of Class A and B refer to -200 to +600 °C (Pt100)

Temperature - Type K TC

Measuring range

-58.0° to 248.0 °F / -50 to +120 °C

Accuracy

Class 1 ¹⁾

Reaction time

90 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K)

Temperature - Type K TC

Measuring range

-58.0° to 446.0 °F / -50 to +230 °C

Accuracy

Class 2 ²⁾

Reaction time

45 sec

1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).

Thermocouples

Temperature - Type K TC

Measuring range

-58° to 752 °F / -50.0 to +400.0 °C

Accuracy

Class 2 ¹⁾

Reaction time

5 sec

1) According to standard EN 60584-2, the accuracy of Class 2 refers to -40 to +1200 °C.

Measurement of the heating of electronic components

Advantages of testo 735:

  • Large range of probes available (incl. surface probes in the most varied shapes; see probe tab)
  • Memory and analysis functions via a PC (testo 735-2)
  • Display, saving and printout of Delta T, min., max. and mean values
  • Can be used universally

Calibration of stationary temperature probes

Advantages of testo 735:

  • For extremely accurate measurements: a system accuracy of 0.05 °C is achieved with a resolution of 0.001 °C using the plug-in high-precision Pt100 immersion/penetration probe 0614 0235
  • Can be used universally
  • It is available in two versions: the testo 735-2 also offers memory and analysis functions via a PC

Measuring temperature in a chemical laboratory

Advantages of testo 735:

  • For extremely accurate measurements: a system accuracy of 0.05 °C is achieved with a resolution of 0.001 °C using the plug-in high-precision Pt100 immersion/penetration probe 0614 0235 .
  • Can be used universally
  • Available in two versions

Temperature measurement in the cosmetics industry

Advantages of testo 735:

  • For extremely accurate measurements: a system accuracy of 0.05 °C is achieved with a resolution of 0.001 °C using the plug-in high-precision Pt100 immersion/penetration probe 0614 0235
  • Can be used universally
  • It is available in two versions: the testo 735-2 also offers memory and analysis functions via a PC
  • IP 65 = to meet cleaning requirements in the pharmaceuticals industry

Temperature distribution in refrigerators and conditioning cabinets

Advantages of testo 735:

  • 3 probe connections for plug-in probes + up to 3 radio probes can be connected
    → Variety of probes are possible
  • It is available in two versions: the testo 735-2 also offers memory and analysis functions via a PC→ Online measurements are possible
  • Memory and analysis functions via a PC (testo 735-2); display, saving and printout of Delta T, min., max. and mean values

Calibration of stationary temperature probes

The testo 735 temperature measuring instrument is also ideally suited for calibrating stationary temperature probes: a system accuracy of 0.05°C is achieved with a resolution of 0.001°C using its plug-in high-precision Pt100 immersion/penetration probe (0614 0235).

Measurement of the heating of electronic components

The testo 735 temperature measuring instrument offers a large selection of probes, has memory and analysis functions available via a PC (testo 735-2) and can display, save and print out Delta T, min., max. and mean values.

Temperature distribution in refrigerators and conditioning cabinets

The testo 735 temperature measuring instrument has 3 probe connections for plug-in probes. In addition, up to 3 radio probes can be connected. It is available in two versions: the testo 735-2 also has memory and analysis functions via a PC and enables display, saving and print-out of Delta T, min., max. and mean values.

Measuring temperature in a chemical laboratory

The testo 735 temperature measuring instrument is ideally suited for laboratory measurement: a system accuracy of 0.05°C is achieved with a resolution of 0.001°C using its plug-in high-precision Pt100 immersion/penetration probe (0614 0235).

Temperature measurement in the cosmetics industry

The high-precision testo 735 temperature measuring instrument enables a system accuracy of 0.05°C with a resolution of 0.001° using its plug-in high-precision Pt100 immersion/penetration probe 0614 0235. It is available in two versions – the testo 735-2 also offers memory and analysis functions via a PC. Both versions meet cleaning standards in the pharmaceutical sector (IP 65).

Product Brochures